31
PROBLEM
CAUSE
SOLVING
5. Device does not
regenerate.
1. Power supply stopped.
1. Check the power supply.
2. Salt in insufficient quantity in the
tank.
2. Check the salt level and fill the
salt tank.
3. Brine is not partially or totally
drawn during the regeneration
stage.
3. See paragraph 6.
4. The control valve is defective or
the settings were changed.
4. Check the control valve and
settings.
5. The salt tank was not supplied
with water or is insufficiently sup-
plied with water.
5. See paragraph 7.
6. Brine is not totally or
partially drawn during
the regeneration stage.
1. Low pressure in the water supply
installation.
1. Check the supply pressure.
2. Blocked/clogged brine injector
or tube.
2. Clean the brine injector and/or
tube.
3. Air/aeration valve blocked with
salt crystals.
3. Clean the air/aeration valve.
4. High pressure loss (blocked
control valve, filtering agent or
distributors).
4. See paragraph 1.4.
5. The brine line is not tight, and air
is also injected as such.
5. Check packing.
6. Settings were modified.
6. Contact the producer.
7. The salt tank is not
sufficiently loaded or not
at all with water.
1. Low supply water pressure.
1. Check the network pressure.
2. Clogged brine injector or tube.
2. Clean the brine injector or tube.
3. Blocked aeration device.
3. Check and clean the aeration
device.
4. Settings were modified.
4. Contact the producer.
5. Float remained blocked.
5. Draw the float (upwards) on the
rod.
8. Excessive salt
consumption during
regeneration.
1. Settings were changed.
1. Contact the producer.
2. The salt tank is loaded with more
water than needed.
2. See paragraph 9.
9. The salt tank is load-
ed with more water than
needed.
1. Pressure of supply water too
high.
1. Check the supply pressure.
2. Settings were modified.
2. Contact the producer.
10. Water has a salty
taste.
1. The filtering agent was not suffi-
ciently rinsed.
1. Increase the operation time
[Rinse]
2. Low output during washing.
2. Check and clean DLFC.
11. Water permanently
flows through dis-
charge.
1. The power supply was cut during
regeneration.
1. Put the valve on by-pass up to the
power supply.
2. The packing of the distance meter
assembly is damaged.
2. Check and replace the damaged
packing.
12. Lack of information
on display.
1. Voltage absence.
1. Check the power supply both of
the electric network and the valve.
2. Defective transformer.
2. Replace the transformer.
3. Defective electronic plate.
3. Replace the electronic plate.
13. The message
[System maintenance]
appears on display.
1. Soft error
1. Restart the voltage supply.
Summary of Contents for CONFORT Series
Page 63: ...63 2 2 1 2 2 1 4 100 12 1 4 2 3 12 99 5 NaCl 2 4 2 5 service bypass 3 5 12 12 22...
Page 68: ...68 3 5 4 09 00 CC 07 09 00 IM 01 12T 09 00 IM 01 12T 09 00 VM 01 12T...
Page 69: ...69 4 1 2 REGION 3 4 5 6 7 REG CAP 8 9 10 11 12...
Page 71: ...71 4 5 6 Figure 5...
Page 75: ...75 AquaPUR SC Valrom Industrie SRL www valrom ro www aqua pur ro 1 aquaPUR CONFORT BG...
Page 77: ...77 2 2 1 2 2 1 4 100 12V 1 4 2 3 12 99 5 NaCl 2 4 2 5 bypass 3 5 12 12 22...
Page 82: ...82 3 5 4 09 00 CC 07 09 00 IM 01 12T Tone 09 00 IM 01 12T Tone 09 00 VM 01 12T Tone...
Page 83: ...83 4 1 2 REGION 3 4 5 6 7 REG CAP 8 9 10 11 12...
Page 85: ...85 4 5 6 Figure 5...
Page 88: ...88 6 SOFT 42 dH 0 20 0 05 6 SOFT 42 dH 0 20 0 05 Valrom Tel 4 0724 200 005...