SAFETY

 

Soft wall coverings (e.g. embossed vinyls etc.) are easily affected by heat.  They may, therefore, scorch or become
discoloured when close to a heating appliance.  Please bear this is mind when having a heating appliance installed and
when redecorating.

 

As with any gas fire, this appliance must be installed by a competent person in accordance with the latest edition of the
Gas Safety (Installation & Use) Regulations and in accordance with the installation guide supplied with this appliance.

 

A shelf made of wood or other combustible material may be fitted above the fire provided that the following conditions
are satisfied:-
For a shelf not more than 150mm deep, there is at least 75mm clearance above the extreme top surface of the fire.  For
a shelf of greater depth, there is an additional clearance of 12.5mm for each extra 25mm of added shelf depth.
Please bear this in mind if you alter the room.

 

A minimum clearance of 150mm must be allowed each side of the fire for ease of servicing and to give easy access to
the control. Please bear this in mind if you alter the room.

 

The space behind the case must not be filled in. Please bear this in mind if you alter the room.

 

The fire should not be used without the ceramic fuel effect pieces in their correct positions or with damaged pieces.

 

The fire must never be used without the glass window in position or with damaged glass.  If the glass is damaged the
fire should be switched off and not used until the glass is replaced.

 

The glass panel acts as a fireguard conforming to BS 1945: 1971 and satisfies the Heating Appliance (Fireguard)
(Safety) Regulations 1991 but does not give full protection for young children, the elderly or the infirm.  Extra security
can be provided by fitting a fireguard which complies with the requirements of BS 6539 (Fireguards for use with Solid
Fuel Appliances) 1984.  Such a fireguard is also recommended for the protection of pet animals.

 

The glass window, and areas surround the firebox and hood opening become very hot when the fire is in use.  Always
switch the fire off and allow to cool before handling.

 

No attempt should be made to clean the bright metal interior of the firebox with metal polish or other abrasives.  After
a little use the interior of the firebox will colour.  This is quite normal.

 

Never obstruct any of the openings of the fire casing by hanging clothing, towels etc. over them.

 

This appliance is fitted with a device which will automatically shut off the supply of gas to the fire if, for any reason, the
burner goes out or the flue is faulty.  If this device does operate or if the fire is turned off accidentally or intentionally,
always wait three minutes before attempting to relight.

Please Note

When your fire is operated for the first time, some vapours may

be given off which might cause a slight odour and could possibly

set off any smoke alarms in the immediate vicinity.  These

vapours are quite normal with new appliances.  They are totally

harmless and will disappear after a few hours use.

Glass Window

As with all windows, the glass may need to be cleaned both

outside and inside from time to time.  The window and frame on

this appliance has, therefore been designed to be customer

removable allowing you to clean it without having to call in a

service engineer.  Details of how to remove the window unit are

given further on in this booklet.

Summary of Contents for 495

Page 1: ...eep for future reference This Owner Guide gives sufficient details to enable your gas fire to be operated and maintained IMPORTANT Please keep your Owner Guide in a safe place together with the Instal...

Page 2: ...r assistance or any advice about gas in general the Valor AdviceLine will be pleased to help Please telephone 0345 626341 local call rates apply FOR OTHER USEFUL TELEPHONE NUMBERS SEE INSIDE BACK COVE...

Page 3: ...pliance Fireguard Safety Regulations 1991 but does not give full protection for young children the elderly or the infirm Extra security can be provided by fitting a fireguard which complies with the r...

Page 4: ...gas appliances These instructions are provided to help you in operating and looking after your new fire and should be kept in a safe place together with the installation and servicing instructions for...

Page 5: ...ss the control knob Turn anticlockwise until resistance is felt just before the IGN position Keep the knob depressed for a few seconds to allow the gas to flow to the pilot then keep the knob depresse...

Page 6: ...ar the location brackets o the window frame sides Pull the bottom of the trim forward slightly and then pull down to clear the outer case hood see Fig 4 2 7 2 Light the spill and insert through the op...

Page 7: ...lace the window unit Locate its bottom edge in the support channels at the firebox sides Refit the two knurled screws and tighten 3 1 5 Replace the window surround 3 2 Cleaning the fuel effect pieces...

Page 8: ...rest on the ridges at each side of the location well marked B in the coal bed 4 1 3 Position the front left coal embossed C on its underside in the well in the coal bed marked C see figure 9 The narro...

Page 9: ...coal embossed E on its underside see figure 11 The groove underneath coal E should locate over the narrow ridge also embossed E situated toward the rear left of the coal bed The left side of coal E s...

Page 10: ...ront burner tubes Fig 13 Centre the log so that the gap to the firebox walls is the same at each side 4 2 3 Place the cross log in position see Fig 14 The front of this log is indicated by the letter...

Page 11: ...he fire until the installation and appliance have been thoroughly checked by a competent person in the U K a CORGI registered installer The following spare parts can be fitted by the user It is essent...

Page 12: ...ghest Standards Valor is a member of the Society of British Gas Industries which works to ensure high standards of safety quality and performance Careful Installation Valor is a Corgi registered compa...

Reviews: