Installation Planning
Venting
43” (1093 mm) to underside of combustible cavity
55-1/2” (1410 mm) with 12” vent pipe
37” (940 mm)
Required
1” clearance
from vertical
pipe to
combustible
material set
E\VWDQGR
12” pipe section
14-1/2” (369 mm)
6WDQGR
9-3/8”
(238 mm)
19-1/4” (489 mm)
Fireplace
1” clearance required
from vertical pipe to
combustible surfaces
This surface is
NOT A SHELF
43” (1093 mm) to underside of combustible cavity
58” (1473 mm) with 12” vent pipe
36-1/2” (927 mm)
2-1/2”
(64 mm)
14-1/2” (369 mm)
9-3/8”
(238 mm)
19-1/4” (489 mm)
Fireplace
12” pipe section
1” clearance required
from vertical pipe to
combustible surfaces
This surface is
NOT A SHELF
Notes—ALL venting considerations
• Dimensions of venting are based on us-
ing Dura-Vent elbows. Elbow curve radius
dimensions will vary when using other
brands and in general are slightly bigger.
• Minimum 12 inches vertical pipe section
required right at unit. Refer to venting chart
on page 28 for allowable horizontal runs.
• 3 inches to combustibles required above
horizontal pipe. Slope pipe upwards 1/4
inch per foot. 1 inch clearance required
around sides and bottom of horizontal pipe
and around vertical pipe.
• When calculating e
ff
ective pipe lengths
subtract approximately 1-1/2 inch per pipe
joint - for example, a 12 inches pipe sec-
tion will add approximately 10-1/2 inches
overall.
Venting Considerations—Vertical Takeo
ff
Venting Considerations—Horizontal Takeo
ff
WARNING
If installing with a horizontal
surface above the fireplace, do
not use this surface as a shelf.
Do not place objects above the
fireplace as this surface will be
hot.