11
Bottom of Unit
0 2” 4” 6” 8” 10”12”
Face of 1/2” thick
non-combustible
cement board
Do not put
furniture or objects
within 36” [914 mm]
of front of appliance
Mantel Projection
(from Face of Cement Board)
Mantel
Height
(from
Bottom
of Unit)
Fireplace
Opening
Fireplace
Opening
Ceiling
36” Min. to Ceiling
44”
42”
40”
38”
33”
23-7/8”
9-3/8”
4” minimum to
combustible or
non-combustible hearth
Same dimensions and restrictions
apply to both sides of the appliance
Combustible Mantel—Left Side View
Installation Planning
Mantel Clearances
NOTE
Use for the optional HeatShift System
affects mantel and hearth clearances. See
HeatShift section in Appendix D of this
manual.
WARNING
HeatShift System MUST be installed on
this appliance when using 1530CIK—Clean
Installation Kit!