9. PREPARING APPLIANCE FOR INSTALLATION
1.
Remove the two screws to the side of the burner unit.
2.
Detach the burner unit from the hotbox by lifting clear.
3.
It is important that the grommet supplied in the loose parts pack is fitted to
the hole in the rear of the hotbox.
4.
For concealed connection only: Pierce the grommet to allow the pipe to pass
through it. The grommet should envelop the pipe. If the hole is larger than the pipe,
seal it with tape.
Do not pierce the grommet unless
the supply pipe is to pass through it
.
5.
The appliance is supplied with two fireback spacers.
Do not fit the fireback spacers if the fire is to be
installed into a precast or clay flue block system as
in section 4.2.4
. These should extend backwards to
ensure sufficient clearance from the back of the fireplace.
Remove the label and retaining screws from the rear
sides of the hotbox. Position the fireback spacers as
shown in figure 9. Secure the fireback spacers using the
screws removed previously, and the two supplied with
the fire.
6.
This appliance is supplied with a flue restrictor for use
where the flue draught is excessive. The restrictor must
NOT be fitted where a precast flue or a flue liner is used.
For all other installations the restrictor
should be fitted. There may however, be
certain circumstances where fitting the
restrictor causes the fire to fail the spillage
test. In such cases the restrictor will have to
be removed. After removal conduct the
spillage check again.
The restrictor is packed loose with the
appliance and is fixed with two screws (See
figure 10).
Page 19
INSTALLER GUIDE
©
Baxi Heating U.K. Limited 2007.
Figure 10. Flue restrictor
Figure 9. Fireback spacers