Permissable Cable Length to Voltage drop
Device
Current
Cable
Cable
Cable
Cable
Cable
Cable
Permissible
Composite
Demand
Length
Length
Length
Size
Resistance
Parallel
Voltage Loss
Resistance
AMPS
25.00
40.00
75.00
Value
Camera
0.11
0.47
0.76
1.42
7/0.2
0.086
1
2
0.09
0.12
0.26
0.41
0.77
7/0.2
0.086
2
2
0.04
0.16
0.23
0.37
0.69
7/0.2
0.086
3
2
0.03
Monitor
0.6
2.58
4.13
7/0.2
0.086
1
3
0.09
0.6
1.29
2.06
3.87
7/0.2
0.086
2
3
0.04
0.6
1.29
2.06
3.87
14/0.2
0.043
1
3
0.04
Door
0.3
0.65
1.03
1.94
14/0.2
0.043
1
3
0.04
Latch
0.5
0.54
0.86
1.61
14/0.2
0.043
2
3
0.02
1
2.15
14/0.2
0.043
1
3
0.04
1
1.08
1.72
14/0.2
0.043
2
3
0.02
Permissable Power Cable Length to Voltage Drop
Permissible
Power
Amps
2.00
4.00
6.00
Size
Resistance
Parallel
Voltage Loss
Supply
2
0.34
0.69
1.03
14/0.2
0.043
1
1
0.04
Amps
3
0.26
0.52
0.77
14/0.2
0.043
2
1
0.02
4
0.40
0.80
1.20
24/0.2
0.025
1
1
0.03
5
0.25
0.50
0.75
24/0.2
0.025
2
1
0.01
6
0.30
0.60
0.90
24/0.2
0.025
2
1
0.01
* Length is calculated to Length / Resistance is Calcuated in Ohms Return (compisite resistance )
Demand
No of
This is a Voltage drop Chart
AMPS
Monitors
Maximum Permissable Voltage Drop
0.6
1
Reccomended Cable length for Signal is
1.2
2
Maximum Length
1.8
3
Monitor To Camera
50
Meters
2.4
4
3
5
Monitor to Monitor
40
Meters
3.6
6
4.2
7
4.8
8
Valet SmartCentre
Video Intercom System
PLEASE READ AND UNDERSTAND THE FOLLOWING
Before installing the Valet Video System we advise that you consult the
table below and take into account the various losses that can occur.
Failure to do this could result in loss of quality and poor performance.
Valet will not be responsible if this information is not strictly adhered too.
12