405
REVO-E Heat pump
4 Function and functional schematics
4.4.1 Heating and Ventilation Mode (HV Mode)
Requirements:
–
Clamp 30 active
–
HV Mode required by BEA body
Both modes are required directly by the BEA body.
CAN messages from the BEA body to SC620 for defined
speed of double radial blowers and position of air flaps
(fresh air / recirculating air).
Water valves are controlled by the BEA body directly.
Fig. 403 Heating and Ventilation Mode (HV Mode)
Double radial blower
Double radial blower
Fresh air
flaps
Sensor
pass. comp.
temperature
Sensor
blow-out
temperature
I/O-A module
Vehicle
Requirement
open / close
Heating valve
actuator
Fresh air
flaps
actuator
Analog input
HVIL 1 voltage
Analog input
HVIL 2 voltage
CAN interface
vehicle
SC620
4
5
1
2
3
6
7
24V
for hot water
heat exchanger
ADA
1 Solenoid valve
2 Solenoid valve HGA / actu-
ator
(in 11123865_only)
3 Suction pressure sensor
4 High pressure safety switch
5 Low pressure safety switch
(
not in 11123865_
)
6 4-way reversing valve
7 High pressure sensor
Summary of Contents for REVO-E
Page 1: ...Rev 06 2019 Id No 11123006A REVO E Heat pump Volvo Workshop Manual AIR CONDITIONING...
Page 51: ...605 REVO E Heat pump 6 Wiring plan Fig 601 Wiring diagram for REVO E HP Sheet 4...
Page 52: ...606 REVO E Heat pump 6 Wiring plan Fig 601 Wiring diagram for REVO E HP Sheet 5...
Page 55: ...609 REVO E Heat pump 6 Wiring plan Fig 602 Wiring diagram for REVO E HP Sheet 1...
Page 56: ...610 REVO E Heat pump 6 Wiring plan Fig 602 Wiring diagram for REVO E HP Sheet 2...
Page 57: ...611 REVO E Heat pump 6 Wiring plan Fig 602 Wiring diagram for REVO E HP Sheet 3...
Page 59: ...613 REVO E Heat pump 6 Wiring plan Fig 602 Wiring diagram for REVO E HP Sheet 5...
Page 87: ...memos...