420
REVO-E Heat pump
4 Function and functional schematics
4.5.3 4-way reversing valve function schematic
Depending on the position, the 4-way reversing valve
activates air conditioning or heat pump operation.
4.5.3.1 Air conditioning mode
.
The 4-way reversing valve is in zero position (not swit-
ched). The system is working in air-conditioning mode.
4.5.3.2 Heat Pump Mode
See
The 4-way reversing valve is in heat pump mode (swit-
ched). The system is in heat pump mode. The refrigerant
circuit works in reverse.
Fig. 415 Function of the 4-way reversing valve - air condtioning