Address
RW
Type
Unit
Register
count
Description
0x0066
R
int16
0.1 µg/m
3
1
Nitrogen dioxide (NO
2
) concentration
calculated from ppb value with linear correction
(register 0x0000)
Calculated by means of selected conversion
type . Calculation method is selected with
register 0x0065
0x0067
R
int16
0.1 µg/m
3
1
Sulfur dioxide (SO
2
) concentration calculated
from ppb value with linear correction (register
0x0001)
Calculated by means of selected conversion
type . Calculation method is selected with
register 0x0065
0x0068
R
int16
1 µg/m
3
1
Carbon monoxide (CO) concentration
calculated from ppb value with linear correction
(register 0x0002)
Calculated by means of selected conversion
type . Calculation method is selected with
register 0x0065
0x0069
R
int16
0.1 µg/m
3
1
Hydrogen sulfide (H
2
S) concentration
calculated from ppb value with linear correction
(register 0x0003)
Calculated by means of selected conversion
type . Calculation method is selected with
register 0x0065
0x006A
R
int16
0.1 µg/m
3
1
Trioxygen (ozone) (O
3
) concentration
calculated from ppb value with linear correction
(register 0x0005)
Calculated by means of selected conversion
type . Calculation method is selected with
register 0x0065
0x006B
R
int16
0.1 µg/m
3
1
Nitric oxide (NO) concentration calculated from
ppb value with linear correction (register
0x0006)
Calculated by means of selected conversion
type . Calculation method is selected with
register 0x0065
0x006C
R
int16
ppb
1
Nitrogen dioxide (NO
2
) concentration in parts
per billion (ppb), without linear correction
• For a value with linear correction, use
register 0x0000
0x006D
R
int16
ppb
1
Sulfur dioxide (SO
2
) concentration in parts per
billion (ppb), without linear correction
• For a value with linear correction, use
register 0x0001
0x006E
R
int16
ppb
1
Carbon monoxide (CO) concentration in parts
per billion (ppb), without linear correction
• For a value with linear correction, use
register 0x0002