Installation and Servicing ecoTEC plus
40
Display
Meaning
Display value/adjustable value
d. 0
Heating part load
Adjustable heating part load in kW (factory setting:
max. output)
d. 1
Water pump over run time for heating mode
2 - 60 min (factory setting: 5 min)
d. 2
Max. burner anti cycling period at 20 °C Flow temperature
2 - 60 min (factory setting: 20 min)
d. 3
Hot water flow temperature reading (when accessories are
fitted)
in °C
d. 4
Current temperature for warm start sensor (when accessories
are fitted) Current storage tank sensor
in °C
d. 5
Flow temperature target value or return target value when
return regulation is set.
in °C, max. the value set in d.71 Limited by the eBUS
controller (if an eBUS controller is connected)
d. 6
Hot water temperature target value
in °C, 35 to 65 °C
d. 7
Warm start temperature target value (when accessories are
fitted) Storage temperature target value (system boiler only)
in °C, 40 to 65 °C in °C, 15 °C for left stop, then 40 to
70 °C
d. 8
External controls heat demand (terminals 3-4)
0 = open (no heat request) 1 = closed (heat request)
d. 9
Flow target temperature from external analogue regulator to
terminal 7-8-9/eBUS
in °C, minimum from ext. eBUS target value and target
value terminal 7
d.10
Status internal heating pump
1 = on, 0 = off
d.11
Status external heating pump
1 to 100 = on, 0 = off
d.12
Cylinder charging pump (via accessory module)
1 to 100 = on, 0 = off
d.13
Hot water circulation pump (via accessory module)
1 to 100 = on, 0 = off
d.22
Hot water demand
1 = on, 0 = off
d.23
Summer/Winter function
1 = Winter, 0 = Summer
d.25
Hot water activation via eBUS Control
1 = yes, 0 = no
d.30
Control signal for both gas valves
1 = on, 0 = off
d.33
Fan speed target value
in rpm/10
d.34
Fan speed actual value
in rpm/10
d.35
Position of diverter valve (when accessories are fitted)
0 = Heating; 100 = Hot water; 40 = Centre position
d.36
Hot water flow sensor
in l/min
d.40
Flow temperature Actual value
in °C
d.41
Return temperature Actual value
in °C
d.44
Digitised ionisation potential
Display range of 0 to 102, > 80 no flame, < 40 even
flame
d.47
Outside temperature (with weather compensating Vaillant
controller only)
Actual value in °C
d.67
Remaining burner anti cycling time
in min
d.76
Appliance variant (device specific number)
00 to 99
d.90
Digital regulator status
1 = identified, 0 = unidentified (eBUS Address <=10)
d.91
DCF status with connected external probe with DCF77 receiver
0 = no reception, 1 = reception, 2 = synchronised, 3 =
valid
d.97
Activation of the second diagnostic level
Password: 17
Table 10.2 Diagnostics codes of the first diagnostic level
10 Troubleshooting
Supplied by HeatingSpares247.com
Summary of Contents for eco TEC plus 415
Page 47: ...Installation and Servicing ecoTEC plus 47 Appendix 14 Supplied by HeatingSpares247 com...
Page 48: ...Installation and Servicing ecoTEC plus 48 Supplied by HeatingSpares247 com...
Page 49: ...Installation and Servicing ecoTEC plus 49 Supplied by HeatingSpares247 com...
Page 50: ...Installation and Servicing ecoTEC plus 50 Notes Supplied by HeatingSpares247 com...
Page 51: ...Installation and Servicing ecoTEC plus 51 Notes Supplied by HeatingSpares247 com...
Page 52: ...0020020828_02 GB 08 2006 Subject to alteration Supplied by HeatingSpares247 com...
Page 54: ...834449_09GB_082006 qxd 10 08 2006 12 20 Seite 2 Supplied by HeatingSpares247 com...
Page 88: ...36 834449_09GB_082006 qxd 10 08 2006 12 20 Seite 36 Supplied by HeatingSpares247 com...
Page 112: ...60 834449_09GB_082006 qxd 10 08 2006 12 20 Seite 60 Supplied by HeatingSpares247 com...
Page 113: ...61 834449_09GB_082006 qxd 10 08 2006 12 20 Seite 61 Supplied by HeatingSpares247 com...
Page 114: ...62 834449_09GB_082006 qxd 10 08 2006 12 20 Seite 62 Supplied by HeatingSpares247 com...
Page 115: ...63 834449_09GB_082006 qxd 10 08 2006 12 20 Seite 63 Supplied by HeatingSpares247 com...
Page 118: ...Supplied by HeatingSpares247 com...
Page 120: ...0020010870 01 GB 03 2006 2 Supplied by HeatingSpares247 com...
Page 138: ...0020010870 01 GB 03 2006 20 Supplied by HeatingSpares247 com...