34
FITTING AIR/FLUE DUCT EXTENSIONS
Offset
Length of
[in mm]
air conduit
[in mm]
Offset
Length of
[in mm]
air conduit
[in mm]
Offset
Length of
[in mm]
air conduit
[in mm]
630
420
635
425
640
430
645
435
650
440
655
445
660
450
665
455
670
460
675
465
680
470
685
475
690
480
695
485
700
490
705
495
710
500
715
505
720
510
725
515
730
520
735
525
740
530
745
535
750
540
755
545
760
550
765
555
770
560
775
565
780
570
785
575
790
580
795
585
800
590
440
230
445
235
450
240
455
245
460
250
465
255
470
260
475
265
480
270
485
275
490
280
495
285
500
290
505
295
510
300
515
305
520
310
525
315
530
320
535
325
540
330
545
335
550
340
555
345
560
350
565
355
570
360
575
365
580
370
585
375
590
380
595
385
600
390
605
395
610
400
615
405
620
410
625
415
Table 6.1: Length of surplus with 87° elbows
> 190 to
< 210 mm
0
> 215 to
not
< 265 mm
possible
> 270 to
< 290 mm
80
295
85
300
90
305
95
310
100
315
105
320
110
325
115
330
120
335
125
340
130
345
135
350
140
355
145
360
150
365
155
370
160
375
165
380
170
385
175
390
180
395
185
400
190
405
195
410
200
415
205
420
210
425
215
430
220
435
225
How to install 87° elbows
Accy. No.: 303 910
☞
Note: The elbow delilvered with
the flue kits 303 933 and
303 936 is not the same
dimension as shown here.
Example:
An offset of 400 mm is measured.
This value is then used, along with the
table below, to determine the length
of the air conduit ( = 190 mm in this
case).
Important:
This gives a corresponding
exhaust-conduit length of
190 + 40 = 230 mm.
Fig. 6.3: Installation of 87° elbows
0
9
1
Offset
Length of air conduit
95
95
10
10
GU_LAZ 102/2GB
834449_09GB_082006.qxd 10.08.2006 12:20 Seite 34
Supplied by HeatingSpares247.com
Summary of Contents for eco TEC plus 415
Page 47: ...Installation and Servicing ecoTEC plus 47 Appendix 14 Supplied by HeatingSpares247 com...
Page 48: ...Installation and Servicing ecoTEC plus 48 Supplied by HeatingSpares247 com...
Page 49: ...Installation and Servicing ecoTEC plus 49 Supplied by HeatingSpares247 com...
Page 50: ...Installation and Servicing ecoTEC plus 50 Notes Supplied by HeatingSpares247 com...
Page 51: ...Installation and Servicing ecoTEC plus 51 Notes Supplied by HeatingSpares247 com...
Page 52: ...0020020828_02 GB 08 2006 Subject to alteration Supplied by HeatingSpares247 com...
Page 54: ...834449_09GB_082006 qxd 10 08 2006 12 20 Seite 2 Supplied by HeatingSpares247 com...
Page 88: ...36 834449_09GB_082006 qxd 10 08 2006 12 20 Seite 36 Supplied by HeatingSpares247 com...
Page 112: ...60 834449_09GB_082006 qxd 10 08 2006 12 20 Seite 60 Supplied by HeatingSpares247 com...
Page 113: ...61 834449_09GB_082006 qxd 10 08 2006 12 20 Seite 61 Supplied by HeatingSpares247 com...
Page 114: ...62 834449_09GB_082006 qxd 10 08 2006 12 20 Seite 62 Supplied by HeatingSpares247 com...
Page 115: ...63 834449_09GB_082006 qxd 10 08 2006 12 20 Seite 63 Supplied by HeatingSpares247 com...
Page 118: ...Supplied by HeatingSpares247 com...
Page 120: ...0020010870 01 GB 03 2006 2 Supplied by HeatingSpares247 com...
Page 138: ...0020010870 01 GB 03 2006 20 Supplied by HeatingSpares247 com...
Page 158: ...Notes 0020010870 01 GB 03 2006 40 Supplied by HeatingSpares247 com...
Page 159: ...Supplied by HeatingSpares247 com...
Page 171: ...Instructions for Use ecoTEC plus 11 Supplied by HeatingSpares247 com...
Page 172: ...0020020829_02 GB 08 2006 Subject to alteration Supplied by HeatingSpares247 com...