Installation Manual auroMATIC 560 0020060907_00
22
Display
Setting by turning the dial
Setting range
Default setting
PROT
Solar circuit safeguard
OFF, 110 °C – 150 °C
130 °C
KOLT:
Collector type
1 = Flat collector
2 = Tubular collector
1, 2
1
LEG
Anti-Legionella function
OFF, 1, 2, 3, 4, 5, 6, 7, 1 – 7
OFF
LEGT:
Start time for the anti-Legionella function
00:00 – 23:50
04:00
Activation of the reheating delay
0=deactivated; 1=activated
0
Activation of activation duration control
0=Off; 1=On
0
Set the current day
1-31
0
Set the current month
1-12
0
Set the current year
2000-2015
2000
Table 6.1 System parameters (continuation)
6 Start-up