Installation Manual auroMATIC 560 0020060907_00
14
Hydraulic plan 2: Connection of a second cylinder or
a swimming pool
LegP
Hg
Sp3
2
2
1
S
Kol 2 Kol 1
Kol2-P
Kol1-P
Sp1
Sp2
LP / UV 1
SR
C1 C2
230 V
EP
Sp3
A
KW
Ertrag
Fig. 5.9 Hydraulic plan 2: Connection of a second cylinder or a
swimming pool
Designation in the
hydraulic plan/con-
nection diagram
Component
C1 C2
Connections for controlling the heating ap-
pliances for recharging the cylinder
Hg
Boiler
KW
Cold water
EP
Electric heating element (optional)
SR
Customer-side swimming pool controller
LP/UV 1
Switching valve
UV 1 in unpowered state
A
Alternative connection for second cylinder
Kol1-P
Solar circuit pump 1
Kol2-P
Solar circuit pump 2
Kol 1
Collector sensor 1
Kol 2
Collector sensor 2
Ertrag
Yield
LegP
Legionella protection pump
Sp1
Cylinder sensor 1
Table 5.6 Key to Fig. 5.9 and Fig. 5.10
Designation in the
hydraulic plan/con-
nection diagram
Component
Sp2
Cylinder sensor 2
Sp3
Cylinder sensor 3
S
Contactor
1
Alternative contactor or Kl 3-4 (old/external
boiler)
2
400 V connection, 3-phase
230 V
230 V mains connection
F1 (T4)
Fuse holder
VC/VK
Connection area for boiler
Table 5.6 Key to Fig. 5.9 and Fig. 5.10 (continuation)
H
Danger
Risk of scalding by hot water
It is imperative that the mixer valve is fitted to
ensure protection from scalding.
5 Electrical installation
Summary of Contents for auroMATIC 560
Page 1: ...auroMATIC 560 VRS 560 ES GB ...
Page 2: ......
Page 4: ......
Page 16: ......
Page 44: ......
Page 46: ......
Page 84: ...0020060907_00 ESGB 122007 ...