7
PEM4.8 Touch Screen
Drawing 0815-1025 (section 17)
Supply voltage
115-230 VAC to power supply unit
Dimensions
218,16 x 162,67 x 46,5 mm (w x h x d)
Cut out
167 x 116 mm (w x h)
Cut out depth
32 mm
Front panel thickness
17 mm
Connections
RJ45 Ethernet connection on the back-bottom side of the panel
Temperature range
-10ºC up to +50ºC
Display
Color TFT LCD,
Touch screen 8” (1024 x 600 dots) with
adjustable backlight
Net weight
940 g
PEM4.10 Touch Screen
Drawing 0815-1026 (section 17)
Supply voltage
115-230 VAC to power supply unit
Dimensions
260 x 178 x 44 mm (w x h x d)
Cut out
246,5 x 164,5 mm (w x h)
Cut out depth
46 mm
Front panel thickness
3,20 mm
Connections
RJ45 Ethernet connection on the back-bottom side of the panel
Temperature range
0ºC up to +50ºC
Display
Color TFT LCD,
Touch screen 10.1” (1280 x 800 dots) with
night view
Net weight
2 kg
4.
SAFETY INSTRUCTIONS
There are no special safety instructions for the equipment.
5.
UNPACKING
Let the equipment acclimatize inside the closed box for at least one
hour at the location where the system
will be installed.
When the equipment is taken out of the box, please leave the special protection supplied with the
equipment as long as possible in place to avoid any damage.
The special protection should be stored for the unlikely event the equipment has to be sent for repair.
Dispose of the packing material should be done according to the laws of the country where the equipment
is installed, or according to the rules that are applicable on the vessel.
•
Be careful when unpacking the electronic equipment. The content is fragile.
•
Do not press on the PEM4 touch screen.
•
Be careful not to damage any of the connectors, control modules or wiring.
6.
INSTALLATION AND FIRST USE
The PEM4 + SPU3 system will be delivered with the software and correct data settings installed. First
connect all the inputs and outputs to the components. Connect for the PEM4.10 version a grounding
cable to the grounding screw on the backside of the screen, see section 17 drawing 0815-1126.
The power supply wires should be connected at last.
Note: There is an ON/OFF switch on PEM4 touch screen. When the power switch is switched ON the
screen will turn on.