35
7.6.5 Signals (raw) menu
Within the Alarms menu you will also find the
Raw signals submenu
, which allows you to monitor the raw
signals coming in from the T-Sense
®
torque sensor or TT-Sense
®
torque and thrust sensor. Also other
signals like the pulses and temperature of the flow meters,
density, ships’s speed and other sensors.
In the
Signals (raw) submenu
“Flow” you can look up the actual flow meter measurements in l/min per
flow meter and the corresponding temperature of the fuel inside the specific flow meter. This amount is
not yet compensated for gravity change due to temperature deviations of the fuel. Flow values will be
converted to a
reference temperature of 15.6°C
if temperature sensors are incorporated in the fuel
system. The difference between the Supply flow and Return flow values represents the fuel consumption
per engine.
Figure 46
–
Raw
Torque
signals screen
Figure 47
–
Raw
Flow
signals screen
Figure 48
–
Raw
Density
signals screen
Figure 49
–
Raw
Ship’s
speed signals screen
Figure 50
–
Raw
Power
signals screen
Figure 51
–
Raw
Draft
signals screen
Figure 52
– Raw Inclinometer signals screen
Figure 53