6.5 CABLE SPECIFICATIONS
Specification of the input, output and power supply cables used for connecting the PEM4 + SPU3 system.
Figure 8
–
Specification of input/output cables at Control box, SPU3 and PEM 4 touch screen(s)
1)
Number of flowmeters can add up to max. 12 for 8 engines or consumers
2)
Optional
3)
When used with VAF Datalogger, please refer to SIG 918 for PC settings and connections
4)
Pulse and PT100 signals should not be joined within 1 pair
Cable specification
IC-01
Integrated antenna cable 5m
VAF supply
IC-02
Integrated stator cable 5m
VAF supply
IC-03
Power supply (115 / 230 VAC) cable
3 x 1,5 mm
2
IC-04
Modbus connection cable
1 x 2 x 0,50 mm
2
, twisted pair, braid shielded
IC-05
Flowmeter cable for pulse and PT100
(3m integrated),
2 x 3 x 0,50 mm
2
or 4 x 2 x 0,50 mm
2
, individual screened twisted pair,
braid shielded
4)
IC-06
Connection cable GPS or speed log
1 x 2 x 0,50 mm
2
twisted pair, braid shielded
IC-07
Connection cable shaftgen. 4-20mA input 1 x 2 x 0,50 mm
2
twisted pair, braid shielded
IC-08
Ethernet cable
CAT5e braid shielded, RJ45 plug
IC-09
From Power Supply Unit 24 VDC cable
5)
2 x 0,50 mm
2
All screens to be connected under the cable gland on the SPU3 side only.
Cable glands are M20 for cable dia. 7-12 mm.
Note: The maximum number of analogue inputs is 9 inputs, depending on the system