![background image](http://html1.mh-extra.com/html/vaf-instruments/667/667_instructions-for-installation-operation-and-maintenance_3144763041.webp)
40
Total volume flow
𝑽 = ∑ ∆𝑽
(F4)
V
= Total Volume
[litres]
D
V
= Volume from one measurement
[litres]
Volume flow rate
𝑸 =
∆𝑽
∆𝒕
(F5)
Q
= Flow rate
[l/sec]
D
V
= Volume from one measurement
[litres]
D
t
= Sample rate
[sec]
𝑸
𝒕𝒄
= 𝑸 ∙
𝜸
𝒕
𝜸
𝟏𝟓.𝟔
(F6)
Q
tc
= Temperature compensated flow rate
[l/sec]
Q
= Flow rate
[l/sec]
15.6
= Specific gravity at reference temperature
[kg/l]
t
= Specific gravity heated to a temperature
[kg/l]
or:
𝑸
𝒕𝒄
= Q
𝟏
𝟏+(∆𝑻 ∙
𝒈𝒄
𝟏𝟎𝟎
)
(F7)
D
T
= Temperature difference
[°C]
gc
= Thermal expansion (Gravity change)
[%/°C]
∆𝑽
𝒕𝒄
= ∆𝑽 ∙
𝜸
𝒕
𝜸
𝟏𝟓.𝟔
(F8)
D
V
tc
= Temperature compensated volume
[litre]
D
V
= Volume from one measurement
[litres]
15.6
= Specific gravity at reference temperature
[kg/l]
t
= Specific gravity heated to a temperature
[kg/l]
or:
∆𝑽
𝒕𝒄
= ∆V
𝟏
𝟏+(∆𝑻 ∙
𝒈𝒄
𝟏𝟎𝟎
)
(F9)
D
T
= Temperature difference
[°C]
gc
= Thermal expansion (Gravity change)
[%/°C]