Troubleshooting
98
Ver.2 01.11.2002
6.3
Alarm list
2 Low seed level, right-hand
side.
- Check the seed level of the seed hopper.
If there is seed in the seed hopper:
- The sensitivity of the sensor has been incorrectly set.
3 Low seed level, left-hand side.
- See alarm no. 2.
9 The left seed box does not ro-
tate.
If the seed box does not move:
- Check whether the transmission between the drive
wheel and the seed box is intact.
If the alarm is generated even
though the seed box rotates:
- Check which alarm time has been programmed.
- Check the cables, connectors and connections.
- Check the operation of the sensor. The LED of the
sensor should light when the toothed plate passes. The
distance between the sensor and the toothed plate
should be 1 - 2 mm. Adjust if necessary.
A lit LED, however, is not necessarily any guarantee
that the sensor is operating.
- Check the condition and mounting of the toothed
plate.
10 The right seed box does not
rotate.
- See alarm no. 9.
14 Tramlining, right.
- The alarm is generated if tramlining does not take
place when the Control Station outputs a tramline sig-
nal or if tramlining takes place when the Control Sta-
tion does not output a tramline signal.
- Check the function of the tramline components in the
distributor head: motor, turn plate, springs and doors.
Clean if necessary.
- Check the cable, connector and connection of the sen-
sor.
- Check the sensor.
15 Tramlining, left.
- See alarm no. 14.
Summary of Contents for Rapid RDA 800S
Page 2: ...2 Ver 2 01 11 2002 ...
Page 4: ...4 ...
Page 73: ...RDA 500 800 S Ver 2 01 11 2002 73 ...
Page 75: ...RDA 500 800 S Ver 2 01 11 2002 75 Figure 5 4 ...
Page 105: ...RDA 500 800 S Ver 2 01 11 2002 105 ...
Page 108: ...Appendices 108 Ver 2 01 11 2002 7 3 2 Hydraulic diagram RDA 800 S Figure 7 2 428718 ...
Page 121: ......