3.19.2
PTO driven hydraulic fan (option)
Connection of the hydraulic pump to the PTO shaft:
Connect the hydraulic pump as explained below. Items 3 and 4 should only be performed during
initial installation or when the pump is moved from one tractor to another.
1 Install the hydraulic pump on the tractor's 1000 rpm PTO shaft. Ensure that the coupling prop-
erly connects with the shaft.
2 Install the top rod in the top rod mount of the tractor. Please note the use of two mounting
points.
3 Install the hydraulic pump to the top rod. Select the most suitable position between A and B.
Do not tighten the screws. Suspend the pump allowing it to lean slightly upwards, approx. 5°
from horizontal. Secure the rod C with the bolts.
4 Let go of the hydraulic pump and tighten the four bolts D.
Verify that the pump is horizontally suspended and does not incline upwards.