12
Alarm list
21. Seed feed rotation LH
If the metering units do not move:
Check that the toothed coupling between the hydraulic motor and the feed
shaft is in the correct position and intact.
If the alarm appears although the
seed meters:
Check the alert time that has been programmed.
Check the sensor. The sensor is
located in the tramline coupling:
Check connections and connectors to the tramline coupling.
The sensor in the coupling could be defective.
The coupling could be defective. Check that the roller in the coupling is
rotating with the feed shaft. The roller should rotate when tramlining is off.
22. Seed feed rotation RH
If the metering units do not move:
Check that the toothed coupling between the hydraulic motor and the feed
shaft is in the correct position and intact.
If the alarm appears although the
seed meters:
Check the alert time that has been programmed.
23. Seed feed rotation LH and RH
If the metering units do not move:
Check that the toothed coupling between the hydraulic motor and the feed
shaft is in the correct position and intact.
If the alarm appears although the
seed meters:
Check the alert time that has been programmed.
Check the sensor. The sensor is
located in the tramline coupling:
Check connections and connectors to the tramline coupling.
The sensor in the coupling could be defective.
The coupling could be defective. Check that the roller in the coupling is
rotating with the feed shaft. The roller should rotate when tramlining is off.
31. Seed feed BioDrill Rotation LH
If BioDrill is not in use:
Turn off the alarm function. Go to the programming menu on the control unit
and switch off BioDrill.
If the metering units do not move:
Check that the toothed coupling between the hydraulic motor and the feed
shaft is in the correct position and intact.
If the alarm appears although the
seed meters:
Check the alert time that has been programmed.
Check the cables, contacts and connection.
Check the operation of the sensor. The sensor LED should light when the
toothed plate passes. The distance between the sensor and the pulse disc must
be 1–2 mm. Adjust if necessary. An illuminated diode is no guarantee that the
sensor is working properly.
Check the condition and installation of the toothed plate.
32. Seed feed, BioDrill rotation RH
If BioDrill is not in use:
See alarm no. 31
32