24. Temperature too high:
fertiliser
The machine will not start or stops because the system has been overloaded.
Check and clean the output unit if it has stopped.
Wait until the machine has cooled down. Upper limit 80°C.
25. Temperature too low:
seed
The machine will not start because the temperature has dropped below the permissible
limit (-5°C) for an appropriate output working temperature
26. Temperature too low:
micro-granulate
The machine will not start because the temperature has dropped below the permissible
limit (-5°C) for an appropriate output working temperature.
27. Temperature too low:
fertiliser
The machine will not start because the temperature has dropped below the permissible
limit (-5°C) for an appropriate output working temperature.
28. Fan speed too high
The fan’s speed is higher than the set
upper
alarm level.
Check the alarm limit settings that are programmed in the menu for alarm levels.
29. Fan speed too low
The fan’s speed is lower than the set
lower
alarm level.
Check the alarm limit settings that are programmed in the menu for alarm levels.
Check the rotation speed sensor cable, connectors and connections.
Check the sensor’s functionality by rotating the fan wheel manually and checking the
diode on the sensor. The diode should light up when the pin on the fan shaft passes the
sensor. The gap between the sensor and the pin should be between 1 and 2 mm. Adjust
if necessary. An illuminated diode is no guarantee that the sensor is working properly.
If the alarm appears only occasionally, this is probably because the sensor is either
incorrectly adjusted or defective.
30. Feed stop
Level for low lift or low stop has not been reached within the preset time limit. Time
limit 10 seconds.
31. Blocked hole in seed
disc in seed meter
One or more holes in the seed disc are clogged.
Check the seed disc and remove seeds or seed residue that have become stuck.
34. Rotation sensor seed
If
the seed discs are not
moving:
The seed disc is jammed.
Check the power supply to the output unit.
Check the motor and the cabling to it.
If the alarm appears
despite rotation of the seed
discs:
Check what alarm time has been programmed in the menu for alarm levels.
Check the cabling, connectors and connections.
The sensor is not emitting a signal.
35. Rotation sensor micro-
granulate
If the output
rollers are not moving:
The output roller is stuck.
Check the power supply to the output unit.
Check the motor and the cabling to it.
If the alarm appears
despite rotation of the
output rollers:
Check what alarm time has been programmed in the menu for alarm levels.
Check the cabling, connectors and connections.
The sensor is not emitting a signal.
903075-en-gb; 07.06.2017
57