page 14 of 92
➨
Pumps with 24 V DC motor: The pump has no on/off
switch. The user has to provide a suitable line discon-
nector.
The supply cable (pumps with AC motor) may be fitted
with a molded European IEC plug or a plug suitable for
your local electrical supply. The cable contains wires
color coded as follows: green or green and yellow:
ground; blue or white: neutral; brown or black: hot.
+
Due to the high compression ratio, the pump may gen-
erate overpressure at the outlet. Check pressure com-
patibility with system components (e.g., exhaust pipe-
line or exhaust valve) at the outlet.
+
Do not permit any
uncontrolled pressurizing
. Make
sure that the exhaust pipeline cannot become blocked.
If there is an exhaust isolation valve, make sure that you
cannot operate the equipment with the valve closed to
avoid a
risk of bursting!
+
Keep the electrical power cord away from heated sur-
faces.
• Provide a firm, level platform for the equipment. Check
that the system which you are going to evacuate is
mechanically stable. Check that all fittings are secure.
Ensure a stable position of the pump without any me-
chanical contact other than the pump feet.
• Comply with
maximum permissible pressures
at in-
let and outlet and with
maximum permissible pres-
sure differences
between inlet and outlet. See section
„Technical data“, pg. 25. Do not operate the pump
with overpressure at the inlet.
• Avoid overpressure of more than 17.5 psi absolute (1.2
bar absolute) in the event that gas or inert gas is con-
nected to the pump, to the gas ballast or to a venting
valve.
•
Note
: Flexible elements will shrink when evacuated.
Summary of Contents for MZ 1C
Page 31: ...page 31 of 92 MZ 1C 3 2 7 10 11 6 9 8 ...
Page 32: ...page 32 of 92 MD 1C AK EK 10 3 6 1 8 2 9 7 15 16 17 13 11 8 14 19 18 ...
Page 33: ...page 33 of 92 MD 1C VARIO SP 7 10 6 12 11 8 Ensure sufficient venting of the pump ...
Page 64: ...page 64 of 92 4 3A 5 MD 1C size 2 2x 1 17 mm 14 mm max 1 4 ...
Page 66: ...page 66 of 92 6 7 8 4 6x Clean ...
Page 67: ...page 67 of 92 9 Replacing the diaphragm 10 11 20696828 20696838 ...
Page 68: ...page 68 of 92 12 1 2 3 13 14 Pay attention to number of washers ...
Page 69: ...page 69 of 92 15 16 17 Pay attention to number of washers ...
Page 70: ...page 70 of 92 18 1 2 19 20 4x Replacing the valves and assembling the pump heads ...
Page 71: ...page 71 of 92 21 22 23 ...
Page 73: ...page 73 of 92 27 28 1 2 28A size 2 2x 17 mm 10 mm MD 1C AK EK 5 1x MD 1C ...
Page 74: ...page 74 of 92 29 30 31 Assembling the connecting hose MD 1C AK EK 2x ...
Page 77: ...page 77 of 92 5 6 4 20638821 20638821 ...
Page 89: ...page 89 of 92 ...
Page 90: ...page 90 of 92 ...
Page 91: ...page 91 of 92 ...