ENGLISH
- 45 -
25 - PROGRAMMING
The programming of the functions and times of the unit is carried
out through the configuration menus, accessible and searchable
through the 3 buttons
h
,
i
and
OK
placed next to the display of
the unit.
S1 S2
A1A2
S3 S4 S5 S6 S7 S8 S9 H1H2H3 H4 H5 H6 H7H8 E1 E2 E3 E4 E5 T1 T1
RECEIVER
OVERLOAD
FRONT PANEL
i1
o
i2
o
i3
o
f1
ATTESA
o
f2
o
c1
o
c2
o
U1
U2
U3
Z1
Z2
Z3
Z4
Z5
Z6
W1 W2 W3 W4 W5
MAINS
OUTPUT
MOTOR
F1
F2
F3
MAINS
VOLTAGE SELECTOR
• By pressing
OK
button you can access the programming and
configuration menus of each individual parameters
• By pressing the button
i
you will switch to the next item
• By pressing the button
h
you return to the previous item
m
WARNING: Outside of the configuration menu, the
buttons
h
and
i
activate the motor in DEAD MAN mode.
The button
h
activates the command OPEN and the button
i
activates the command CLOSE.
m
These commands activate the motor without taking
into account the status of safety devices.
25.1 - ACCESS TO MAIN PROGRAMMING
MENUS
1.
Press and hold the OK button until the display shows the
desired menu
PRG
Programming of the operating parameters
(Chapter 25.5)
CNT
Cycle Counter (Chapter 25.4)
SET
Learning of the travel (Chapter 25.3)
DEF
Loading DEFAULT parameters (Chapter 25.2)
2.
Release the
OK
button: the display shows the first item in the
sub-men or the options available for the function.
PRG
MODE
CNT
Total / Service
SET
Learn / Exit
DEF
Load default / Exit
3.
Using the buttons
h
i
and
OK
select and edit the parameters
needed
m
CAUTION: if you do not carry out any operation for
more than 1 minute, the unit exits from the programming
mode, without storing the settings and changes made are
lost.
25.2 - LOADING DEFAULT PARAMETERS
If necessary, you can reset all parameters to their DEFAULT values
(see table on page 46).
m
WARNING: This procedure involves the loss of all
customized parameters.
1.
Press and hold the
OK
button until the display shows
DEF
2.
Release the
OK
button: the display shows
Load default
Exit
3.
To exit the function, select
Exit
using the
h
i
and press
OK
to confirm
4.
To load the DEFAULT data select
Load default
using the
h
i
buttons and press
OK
.
Then select
Yes
and press
OK
: all parameters are re-written
with their DEFAULT value, the unit leaves the programming
mode and the display shows the control panel
25.3 - TRAVEL LEARNING
This function allows you to store the limit switches.
The recorded values are useful for all the programming
parameters that are based on a percentage of the travel.
1.
Press and hold the
OK
button until the display shows
SET
2.
Release the
OK
button: the display shows
Learn
Exit
3.
To exit the function, select
Exit
using the
h
i
and press
OK
to confirm
4.
To start the learning procedure of the travel select
Learn
through the buttons
h
and
i
and press then
OK
5.
Press and hold the
h
button to open the door completely
6.
Press and hold the button
i
to close the door completely
7.
Press the
OK
button: the display shows the value measured by
the obstacle sensor during
SEN.A
opening
8.
- To confirm the value displayed, press the
OK
button, then
select the menu
FINE
and
YES
to store the values of the
sensors, the limits of the travels and exit the function
- To change the value of the parameters
SEN.A
and
SEN.C
use the h and i buttons, press
OK
to confirm, then select
the menu
FINE
and
YES
to store the values of the
sensors, the limits of the travel and exit the function
- To store only the limits of the travel without changing the
obstacle sensor settings, wait 20” without pressing any
button: the unit exits the programming menu and displays
the control panel