3. Diving with Galileo
45
English
4-second intervals. In addition, the current
depth is shown in inverted colors (white on a
black background) and in the lower left corner
MOD
and the value of the MOD are displayed,
also in inverted colors. Alternate information is
accessible as described in section 3.3.2, but
after 5 seconds the inverted MOD is again
shown. This will not change until the diver
ascends 1m/3ft above the MOD. The audible
signal persists until the diver ascends 1m/3ft
above the MOD.
In
LIGHT
confi guration, the alarm message
MOD EXCEEDED
is displayed in place of
the no-stop information for 12 seconds,
after which it is repeated in 4-second
intervals. In addition, the current depth is
displayed in inverted colors (white on a
black background) and remains like this
until the diver ascends 1m/3ft above the
MOD. The audible signal persists until the
diver ascends 1m/3ft above the MOD.
In
FULL
confi guration, the alarm message
MOD EXCEEDED
is displayed in place of
the no-stop or decompression information
for 12 seconds, after which it is repeated in
4-second intervals. In addition, the current
depth is shown in inverted colors (white on a
black background) and
MOD
and the value
of the MOD are displayed in place of the max
depth, also in inverted colors. This will not
change until the diver ascends 1m/3ft above
the MOD. The audible signal persists until the
diver ascends 1m/3ft above the MOD.
3.2.3 CNS
O
2
= 100%
!
WARNING
When the CNS O
2
reaches 100% there is
danger of oxygen toxicity. Start procedure to
terminate the dive.
In
CLASSIC
confi guration, the alarm message
CNS O
2
=
100%
is displayed in place of the
no-stop or decompression information for
12 seconds and during this time the audible
signal goes off. In addition, in the lower left
corner, the CNS O
2
information is displayed in
inverted colors (white on a black background)
and remains displayed until the CNS O
2
value
drops under 100%. Alternate information is
accessible as described in section 3.3.2, but
after 5 seconds the inverted CNS O
2
is again
shown.
In
LIGHT
confi guration, the alarm message
CNS
O
2
=
100
% is displayed in place of
the no-stop information for 12 seconds
and during this time the audible signal
goes off. In addition, after the text
message extinguishes, the CNS O
2
is
displayed in inverted colors (white on a
black background) in the lower left corner,
alternating every 4 seconds with the tank
pressure information. This will remain so for
as long as the CNS O
2
value is higher than
100%. Alternate information is available as
described in section 3.3.3.