© 2018 Utilicor Technologies Inc.
minicor-3 V1.5
34
(4)
It is important to run the entire system with the glycol mixture before
storing the minicor-3, or moving a significant distance during the day.
Wind chill factors can greatly reduce effective temperatures and
increase the likelihood of freezing, so take this into account when
performing the winterizing procedures.
(5)
If you intend to core after the equipment has been winterized, fill the
water tank with warm water and an environmentally acceptable glycol
based additive before leaving for the site. If desired, once the pumps
are turned on, the undiluted glycol in the pipes and hoses can be
collected and saved to be used again. If you are using a diluted
mixture, it can be used to core with.
Note: Depending upon the anticipated temperature, cold weather windshield
washer fluid can be used to treat the system, and will perform adequately as
a winterizing agent in moderately cold temperatures. Follow the temperature
instructions of the manufacturer.
Cold Weather Core Reinstatements
Maintenance
Preventative maintenance not only reduces downtime, but also reduces
overall operating costs.
Here are some general points to keep in mind:
(1)
Rinse out the water tank of sediment after each day's use. This will
help to prevent the contamination of the filter system, and avoid
clogging the water feed assembly.
(2)
Maintain proper fluid levels and follow the lubrication instructions.
(3)
The hydraulic motor assembly / pillow block has a grease nipple, which
should be greased on a monthly basis. Failure to do so may cause
disproportional wear.