2GN/2GP/2GR
1-3-42
U158
Checking the developing count
Description
Displays the developing count for checking.
Purpose
To check the developing count after replacing the developing unit.
Method
Press the start key. The developing counter count is displayed.
Setting
1. Change the setting using the +/- or numeric keys.
2. Press the start key. The count is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
U161
Setting the fuser control temperature
Description
Changes the fuser control temperature.
Purpose
Normally no change is necessary. However, can be used to prevent curling or creasing of paper, or solve a
fuser problem on thick paper.
Method
1. Press the start key.
2. Select the item to be set.
3. Change the setting using the +/- or numeric keys.
4. Press the start key. The value is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
U163
Resetting the fuser problem data
Description
Resets the detection of a service call code indicating a problem in the fuser section.
Purpose
To prevent accidents due to an abnormally high fuser temperature.
Method
1. Press the start key.
2. Press [EXECUTE] on the touch panel.
3. Press the start key. The fuser problem data is initialized.
4. Turn the main power switch off and on.
U167
Checking fuser counts
Description
Displays fuser counts for checking.
Purpose
To check fuser counts after replacing the fuser unit.
Method
Press the start key. The fuser counts are displayed.
Setting
1. Change the setting using the +/- or numeric keys.
2. Press the start key. The count is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Maintenance
item No.
Description
Display
Description
Setting range
Initial setting
DRIVE START TEMP
Driving start temperature when
warm-up starts
0 to 255 (
°
C)
175 (30 ppm)
185 (40/50 ppm)
READY CONTROL T
Control temperature for displaying
[Ready for copying.]
0 to 255 (
°
C)
190 (30 ppm)
200 (40/50 ppm)
PRINT CONTROL T
Control temperature during printing
0 to 255 (
°
C)
190 (30 ppm)
200 (40/50 ppm)
Summary of Contents for CD 1230
Page 1: ...Service Manual Copy CD 1230 CD 1240 CD 1250 Version 1 0 Date 04 07 2006 2GNSM060 ...
Page 2: ...Service Manual Copy DC 2230 DC 2240 DC 2250 Version 1 0 Date 04 07 2006 2GNSM060 ...
Page 4: ...Revision history Revision Date Replaced pages Remarks ...
Page 5: ...This page is intentionally left blank ...
Page 113: ...2GN 2GP 2GR 1 3 82 ...
Page 231: ...2GN 2GP 2GR 2 2 6 ...
Page 253: ...INSTALLATION GUIDE FOR THE DOCUMENT PROCESSOR ...
Page 275: ...INSTALLATION GUIDE FOR BUILT IN FINISHER ...
Page 288: ...INSTALLATION GUIDE FOR JOB SEPARATOR ...
Page 297: ...INSTALLATION GUIDE FOR FAX System M ...