2GN/2GP/2GR
1-4-32
C6050
Abnormally low fuser thermistor 3
temperature
Fuser thermistor 1 is detected 100
°
C/
212
°
F less than 1 s continuously during
copying.
Defective fuser
heater M or S.
Replace the fuser heater M or S.
Installation defec-
tiveness on fuser
thermistor 1.
Check the mounting state of the fuser ther-
mistor 1. If any problem is found, repair it.
Defective PWB.
Replace the power source PWB or engine
PWB and check for correct operation.
C6400
Zero-cross signal error
While fuser heater ON/OFF control is
performed, the zero-cross signal is not
input within 3 s.
Defective PWB.
Replace the engine PWB or power source
PWB and check for correct operation.
C6410
Fuser unit connector insertion prob-
lem
Absence of the fuser unit is detected.
Fuser unit connec-
tor inserted incor-
rectly.
Reinsert the fuser unit connector if neces-
sary.
Defective fuser unit
connector.
Replace the fuser unit.
C6420
Fuser unit fuse cut problem
The fuse in the fuser unit did not blow
within three seconds.
Poor contact in the
connector termi-
nals.
Check the connection of connector YC10 on
the engine PWB and the continuity across
the connector terminals. Repair or replace if
necessary.
Fuser unit connec-
tor inserted incor-
rectly.
Reinsert the fuser unit connector if neces-
sary.
C7300
Toner container problem
Toner level is not detected when toner
empty is detected.
Poor contact in the
connector termi-
nals.
Check the connection of connector YC9 on
the engine PWB and the continuity across
the connector terminals. Repair or replace if
necessary.
Defective toner
container sensor.
Replace the toner container sensor.
C7400
Developing unit connector insertion
problem
Absence of the developing unit is
detected.
Developing unit
connector inserted
incorrectly.
Reinsert the developing unit connector if
necessary.
Defective develop-
ing unit connector.
Replace the developing unit.
C7410
Drum unit connector insertion prob-
lem
Absence of the drum unit is detected.
Drum unit connec-
tor inserted incor-
rectly.
Reinsert the drum unit connector if neces-
sary.
Defective drum unit
connector.
Replace the drum unit.
C7800
Broken external thermistor wire
The thermistor output value is 4.5 V or
more.
Poor contact in the
connector termi-
nals.
Check the connection of connector YC14 on
the engine PWB and the continuity across
the connector terminals. Repair or replace if
necessary.
Defective humidity
sensor.
Replace the humidity sensor.
Code
Contents
Remarks
Causes
Check procedures/corrective measures
Summary of Contents for CD 1230
Page 1: ...Service Manual Copy CD 1230 CD 1240 CD 1250 Version 1 0 Date 04 07 2006 2GNSM060 ...
Page 2: ...Service Manual Copy DC 2230 DC 2240 DC 2250 Version 1 0 Date 04 07 2006 2GNSM060 ...
Page 4: ...Revision history Revision Date Replaced pages Remarks ...
Page 5: ...This page is intentionally left blank ...
Page 113: ...2GN 2GP 2GR 1 3 82 ...
Page 231: ...2GN 2GP 2GR 2 2 6 ...
Page 253: ...INSTALLATION GUIDE FOR THE DOCUMENT PROCESSOR ...
Page 275: ...INSTALLATION GUIDE FOR BUILT IN FINISHER ...
Page 288: ...INSTALLATION GUIDE FOR JOB SEPARATOR ...
Page 297: ...INSTALLATION GUIDE FOR FAX System M ...