Firmware
>
Firmware update
[CONFIDENTIAL]
• In case of occurring an error during the firmware update, the process is immediately interrupted and the error
message and error code are displayed.
*1:
The expiration of the FM certification is also included.
*2:
Since the normal start-up is available next time, it is restarted automatically and starts up normally.
*3: As there is a possibility that normal start-up is impossible next time, without restarting automatically, and
move to USB update mode.
Indication of the signature verification result
3
Unplug the power cord and disconnect the USB memory.
4
Plug in the power cord and turn the power switch (a) on.
5
Check that the “Ready to print” screen is displayed and then turn the power switch (a)
off.
Safe-Update
When the firmware update was interrupted by power shut-off or disconnecting the USB memory during the firmware
update, the firmware update is retried at the next power-on.
Turn the main power on again while the USB memory is installed.
• * The firmware update that was already completed before power shut-down is skipped.
Codes
Description
Codes
Description
0000
Others
S000
Other signature verification error *1
0100
There is no master file.
S001
Official signature verification file is short.
0200
Master file version discrepancy
N001
Unable to connect the network *2
(There is no target to update.)
03xx
There is no download file (No.xx).
04xx
File (No.xx) check sum discrepancy
N002
Can not connect to the network *3
(There is the target to update.)
05xx
File (No.xx) preparation failure
06xx
File (No.xx) preparation failure
08xx
File (No.xx) writing failure
Official signature verification file
Indicate the result
Both certificate and signature files exist and verification is successful.
Version number
Both certificate and signature files exist but verification is unsuccessful.
S000
Neither certificate nor signature files exist.
Or either of them does not exist.
S001
Important
Never turn the power switch (a) off or disconnect the USB memory (b) during the firmware update.
Summary of Contents for CA-3100
Page 118: ...4 20 Maintenance Assembly and disassembly a d c f e e c ...
Page 131: ...4 33 Maintenance Assembly and disassembly a b c c d c ...
Page 134: ...4 36 Maintenance Assembly and disassembly c b a b ...
Page 146: ...4 48 Maintenance Assembly and disassembly Optional items a b c d ...
Page 148: ...4 50 Maintenance Assembly and disassembly Optional items a b c ...
Page 271: ... CONFIDENTIAL 2 IB 51 IB 51 Wireless Interface INSTALLATION GUIDE ...
Page 274: ...付録 Installation guide CONFIDENTIAL 3 IB 32B IB 32B IEEE1284 Interface INSTALLATION GUIDE ...
Page 282: ... CONFIDENTIAL 3 5 6 4 1 2 1 2 3 1mm 㟝㫴G㤵㣠 1 2 㛅 G㣙㾌 PF 3100 㦹㢨G㣰G㥐ᶤ ...
Page 283: ... Installation guide 6 HD 6 HD 7 HD 6 HD 7 INSTALLATION GUIDE ...
Page 285: ... Installation guide 7 CA 3100 CA 3100 INSTALLATION GUIDE ...