![Uson sprint iq Owner'S Manual Download Page 18](http://html1.mh-extra.com/html/uson/sprint-iq/sprint-iq_owners-manual_1064342018.webp)
16
Quick Start
Channel Pass/Fail Messages
These are some of the messages that may appear in the right
column of the channel display.
2.2.8 Test Parameters
Test parameters are setpoints and tolerances that tell Sprint iQ
how to conduct a test and decide whether a product is accepted or
rejected. Test parameters are set in Sprint iQ’s Test Parameters
menu.
When Test Parameters are Available
If existing test values are at hand, begin by simply entering those
values into the Sprint iQ. Once all values are set correctly, the
Sprint iQ is ready for fine tuning.
When Test Parameters are not Available
If there are no established test values, some experimenting is
needed to arrive at values for pressures, flow rates, and times best
suited to the product. Little effort is required to program Sprint iQ
after test parameters are established. Yet, coming up with test
values takes consideration when starting from scratch.
Gross
Pressure fell below minimum
during stabilization phase.
HiBurst
Burst above max setpoint
HiCrack
Crack above max setpoint
LoBurst
Burst below min setpoint
LoCrack
Crack below min setpoint
NoBurst
Burst not detected
NoCrack
Crack not detected
Pass
The last test on this channel passed.
UserAB
Abort:
Stop
switch was pressed.