LPH800 TREATER
PROXIMITY SWITCH ADJUSTMENT GUIDE
The proximity switches mounted in the extension ring and the seed wheel detect when
seed is present.
The proximity switch located in the extension ring is used to automatically shut off the
inlet conveyor when the surge hopper is full. This proximity switch is not present on
tower systems.
The proximity switches located in the seed wheel automatically shut off the pump when
all seed has left the hopper.
If the proximity switch is not working properly, this can be caused by wear, dust, or
even moisture. The first step is to clean the lens of the proximity switch. If this does
not solve the problem, the next step would be to adjust the sensitivity of the proximity
switch.
The green light indicates the power status. If it is active the device is powered.
The amber light indicates when seed is being detected. If it is active it detects seed,
if inactive it does not detect seed.
Using the small screwdriver provided inside the control panel, you can adjust the
proximity switch by turning the adjusting screw on the back of the proximity switch.
Turn Clockwise to make the proximity switch more sensitive.
Turn Counterclockwise to make the proximity switch less sensitive.
Proximity Switch Screwdriver
Sensitivity
Adjustment Screw
Amber light
Green light
Summary of Contents for LPH800
Page 17: ...Page 17 LPH800 TREATER LPH800 MIX TANK PLUMBING 2 3 ...
Page 49: ...Page 49 LPH800 TREATER LPH800 BASE FRAME ASSEMBLY 18 01 0011 2 9 1 19 16 10 17 15 ...
Page 50: ...Page 50 LPH800 TREATER LPH800 BASE FRAME ASSEMBLY 18 01 0011 20 5 2 3 18 12 3 18 13 2 21 2 ...
Page 57: ...Page 57 LPH800 TREATER LPH800 TREATER Drum 41 A DETAIL A 19 4 42 26 ...
Page 60: ...Page 60 LPH800 TREATER LPH800 TREATER Discharge End 44 49 42 52 46 28 23 ...
Page 61: ...Page 61 LPH800 TREATER LPH800 TREATER Forklift Pockets and Bottom Guards 22 15 16 51 22 26 ...
Page 68: ...Page 68 LPH800 TREATER 30 GALLON TANK AND BASE ASSEMBLY 04 03 0199 7 6 5 2 3 8 10 4 1 4 9 ...
Page 70: ...Page 70 LPH800 TREATER LPH CALIBRATION TUBE ASSEMBLY 13 04 0208 4 10 1 3 8 6 7 11 5 2 9 9 ...
Page 74: ...Page 74 LPH800 TREATER NOTES ...