Page 27
LPH800 TREATER
1. PUMP #1 VOLTMETER:
Displays the DC voltage for pump #1. As pump #1 speed
is increased or decreased, this number will also increase or decrease.
2. HAND / OFF / AUTO SWITCH (for Pump #1 & #2):
This switch controls pump #1,
pump #2, and any device connected to the auxiliary port. This switch must be
activated before either pump will operate in forward or reverse.
HAND POSITION:
When the switch is placed in HAND, the pump(s) will run only
when you have turned the pump(s) switch to forward or reverse and the speed has
been adjusted.
AUTO POSITION:
When the switch is placed in
AUTO, the pump(s) will only run when the lower
proximity switch located in the supply hopper is
covered and the atomizer is running. The proximity
switch determines when seed is present in the
hopper. When the proximity switch does not detect
seed, a timer relay located inside the control panel
will automatically shut off the pump(s) a pre
-
determined amount of time after the hopper has
emptied. The timer relay (right) located in the control
panel is set to Mode “D” and has an adjustable knob
with settings from 0
-
6. Each number represents the
number of seconds from the time the hopper empties
until the pumps will shut off. The time delay allows
all seed in the hopper to have an equal coverage.
3. PUMP #1 DIRECTION:
This switch allows the operator to change the pump
direction between forward and reverse. It has a safety feature that will not allow the
operator to switch from forward to reverse or vice
-
versa without momentarily stopping
and releasing the switch in the center position.
4. LIQUID ADJ. PUMP #1:
This dial allows the operator to adjust the speed of
pump #1. The setting should be chosen in relation to the application rate for the
treatment being applied to the seed.
5. PUMP #2 VOLTMETER:
Displays the DC voltage for pump #2. As pump #2 speed
is increased or decreased, this number will also increase or decrease.
6. PUMP #2 DIRECTION:
This switch allows the operator to change the pump
direction between forward and reverse. It has a safety feature that will not allow the
operator to switch from forward to reverse or vice
-
versa without momentarily stopping
and releasing the switch in the center position.
7. LIQUID ADJ. PUMP #2:
This dial allows the operator to adjust the speed of
pump #2. The setting should be chosen in relation to the application rate for the
treatment being applied to the seed.
CONTROL DESCRIPTIONS
Summary of Contents for LPH800
Page 17: ...Page 17 LPH800 TREATER LPH800 MIX TANK PLUMBING 2 3 ...
Page 49: ...Page 49 LPH800 TREATER LPH800 BASE FRAME ASSEMBLY 18 01 0011 2 9 1 19 16 10 17 15 ...
Page 50: ...Page 50 LPH800 TREATER LPH800 BASE FRAME ASSEMBLY 18 01 0011 20 5 2 3 18 12 3 18 13 2 21 2 ...
Page 57: ...Page 57 LPH800 TREATER LPH800 TREATER Drum 41 A DETAIL A 19 4 42 26 ...
Page 60: ...Page 60 LPH800 TREATER LPH800 TREATER Discharge End 44 49 42 52 46 28 23 ...
Page 61: ...Page 61 LPH800 TREATER LPH800 TREATER Forklift Pockets and Bottom Guards 22 15 16 51 22 26 ...
Page 68: ...Page 68 LPH800 TREATER 30 GALLON TANK AND BASE ASSEMBLY 04 03 0199 7 6 5 2 3 8 10 4 1 4 9 ...
Page 70: ...Page 70 LPH800 TREATER LPH CALIBRATION TUBE ASSEMBLY 13 04 0208 4 10 1 3 8 6 7 11 5 2 9 9 ...
Page 74: ...Page 74 LPH800 TREATER NOTES ...