Page 33
LPH800 TREATER
9.
Using the stop watch, determine the pump flow rate. Keeping the pump running,
position the valve on top of mix tank to CALIBRATION TUBE. When liquid reaches
0 (zero) or an even number, begin timing for one minute. (see Figure 1, below)
10. As soon as one minute is up, position valve on top of mix tank to MIX TANK.
Read the level on the side of the calibration tube (see Figure 2, below). This
number should equal the number of ounces needed to flow through the pump in
one minute. If the ounces needed per minute have not been met, re
-
adjust the
pump speed up or down accordingly and repeat steps 9 and 10 until the liquid flow
rate has been matched.
Figure 1
Liquid at 0 oz.
Figure 2
Liquid at 35 oz.
after 1 minute
PUMP #1 CALIBRATION