WIRING FOR DOOR CONTROL
WIRING FOR DOOR CONTROL
Controlling a magnetic fail-safe lock
Door 1:
Terminal n°8: common
Terminal n°9: idle
Door 2:
Terminal n°16: common
Terminal n°17: idle
Controller
IDLE
COMMON
Protecting
diode
cathode
+12V-
DC
Fail-Safe
Lock
Use a power supply suitable for the magnetic lock
We strongly recommend using a separate power supply for the unit and the magnetic lock.
A fail-safe lock (or power to lock) requires a permanent power supply to keep the door locked.
For instance in the event of power failure the door would become unlocked.
Controlling a fail-safe lock
Door 1:
Terminal n°8: common
Terminal n°9: idle
Door 2:
Terminal n°16: common
Terminal n°17: idle
Controller
IDLE
COMMON
Protecting
diode
cathode
+12V-
DC
Fail-Safe
Lock
Use a power supply suitable for the fail-secure lock
We strongly recommend using a separate power supply for the unit and the lock.
A fail-safe lock (or power to lock) requires a permanent power supply to keep the door locked.
For instance in the event of power failure the door would become unlocked.
19
50-000-611 DOC TRANSIT GB FDI
C