WIRING FOR DOOR CONTROL
Controlling a Gate automation (an Open or Closed dry contact is sufficient)
Controlling a fail-secure lock
A fail-secure lock (or power to lock) requires a permanent power supply to keep the door
locked. For instance in the event of power failure the door would become unlocked.
Door 1:
Terminal n°8: common
Terminal n°10: work
Door 2:
Terminal n°16: common
Terminal n°18: work
Controller
WORK
COMMON
Protecting
diode
cathode
+12V-
DC
Fail-Secure
Lock
In case of alternative current power supply, use a variable resistor instead of a diode.
Use a power supply suitable for the fail-safe lock
We strongly recommend using a separate power supply for the unit and the magnetic lock.
Door 1:
Terminal n°8: common
Terminal n°10: work
Door 2:
Terminal n°16: common
Terminal n°18: work
Controller
WORK
COMMON
Door 1:
Terminal n°8: common
Terminal n°9: idle
Door 2:
Terminal n°16: common
Terminal n°17: idle
Controller
IDLE
COMMON
Gate
automated
system
Gate
automated
system
If you need an NO (Normally Open) contact
If you need an NC (Normally Closed) contact