DOOR 1: controlled by channel 1

DOOR 2: controlled by the proximity

1. Entering programming Mode

To program the unit, you must first enter PROGRAMMING mode. In programming mode the keys and remote 

controls are not read and cannot control the doors. The pushbutton operates except during use of functions 

F4

 

and 

F5.

If the unit does not have a password :

Press one of the three programming buttons 

 or  . The unit displays 

00

If the unit has a password :

Enter the password using the three keys. A password is a combination of six pressings on the keys 

 , 

and 

 . For example : 

,  , 

,  , .

If the password is correct, the unit displays 

00

 otherwise it displays 

err

 followed by two series of digits. Try again 

or note these digits to indicate them to your distributor.
You can then use the arrows 

 and 

 to scroll the numbers from 

001

 to

 999

 (or 

500 

depending on the version) 

to store the keys and remote controls and from 

F1

 to 

F5

 to modify the parameters of the unit.

In programming mode, the central point does not indicate the state of the power supply. It is used to indicate that 

a code is read on the programming reader

2. Storing the remote controls

Display a position 

01

 and 

999

 (or 

500 

depending on the version) using the   and   keys. (If the position contains 

a code, at least one of the points on the left or the right of the display lights up. To modify the authorisation, 
press  )

Present the remote control or the proximity key on the reading zone on the right of the readout. After the code 

has been read, the central point lights up. (If the code already exists in the memory, the unit ignores the position 

you have chosen and displays the position at which the code is programmed. You can then modify the authori-

sations).
Use the arrows 

 and 

 to display:

- the point to the left of the readout to authorise Channel 1 on door 1,

- the point to the right of the readout to authorise the Proximity on door 2,

- both points to authorise Channel 1 of the remote control on Door 1and its integrated proximity key on Door 2.

(If you do not authorise any door, the operation will be cancelled) 
Validate with the key  .

  CAUTION : Channel 2 of the remote control cannot be authorised in this configuration. Channel 1 can 

control Door 1 and the proximity key integrated in the remote control or the proximity key can control Door 2.

3. Cancelling a remote control

Display a position between 

01

 and 

999

 (or 

500 

depending on the version) using the arrows  

 and 

.

(If the position contains a code, at least one of the points on the left or the right of the display lights up)
To cancel the code, keep the key   pressed for 1 second: the display flashes once and the

points on the right and the left disappear.

4. Exiting from programming mode

To exit from programming mode, press 

 and 

 simultaneously.

  CAUTION : Exit from programming mode is automatic if no key is pressed for 30 seconds

11

50-000-611 DOC TRANSIT GB FDI

 C

Summary of Contents for FDI Transit FD-010-012

Page 1: ...VIEW TECHNICALFEATURES OPERATING PRINCIPLES IN WHICH CONFIGURATION DO YOU USE TRANSIT CONFIGURATION N 1 CONFIGURATION N 2 CONFIGURATION N 3 CONFIGURATION N 4 CONTROLLER PARAMETERS PROGRAMMATION WIRING...

Page 2: ...nts of the European Community Directive R TTE 99 5 CE Assessment of the product s compliance with requirements based on the following standards Regarding short range devices ETS300683 1997 Regarding r...

Page 3: ...be accessed The system consists of the following parts SPARE PARTS FORTRANSIT 500 GB 100 020 TRANSIT 500 KEYS WITHOUT RF433 FD 020 080 TRANSIT INT MULLION READER FD 020 084 VANDAL RESISTANT READER FD...

Page 4: ...10 to 20m coaxial 50 35 m More than 20m of cable less than 35m 1 2 3 4 5 6 7 8 9 10 1112131415161718 19 20 1 Way for wires 2 Buttons for programming 3 3 digit display 4 Programming reader 5 Fixing hol...

Page 5: ...f a proximity reader connected to door 1 In programming mode indicates access authorisation for door 2 In operation indicates the door opening by a code Power Supply status Dot on correct power supply...

Page 6: ...t is held for one second 5 Access Authorization The numbers 01 to 500 or 01 to 999 depending on the version correspond to locations in which you can store the access authorisation of a remote control...

Page 7: ...mity key or the proximity key integrated in the remote control GO TO PAGE N 10 Door 1 controlled by the proximity key or the proximity key integrated in the remote control Door 2 controlled by channel...

Page 8: ...supply RFAntenna433MHz inoption Coaxcable 50Ohms10mmax Diameter6 10 500mmaxlength Power supply DC power supply 12V DC 0 4 A acceptable range 10 8V to 22V AC power supply 12V AC 12V in nominal value a...

Page 9: ...ition contains a code at least one of the points on the left or the right of the display lights up To modify the authorisation press Present the remote control on the reading zone on the right of the...

Page 10: ...oor1 ExitPB Door2 ExitPB Power supply RFAntenna433MHz inoption Coaxcable 50Ohms10mmax Diameter6 10 500mmaxlength Diameter6 10 100mmaxlength Door 1 controlled by channel 1 Door 2 controlled by the prox...

Page 11: ...the authorisation press Present the remote control or the proximity key on the reading zone on the right of the readout After the code has been read the central point lights up If the code already ex...

Page 12: ...oor1 ExitPB Door2 ExitPB Power supply RFAntenna433MHz inoption Coaxcable 50Ohms10mmax Diameter6 10 500mmaxlength Diameter6 10 100mmaxlength Door 1 controlled by the proximity key or the proximity key...

Page 13: ...horisation press Present the remote control or the proximity key on the reading zone on the right of the readout After the code has been read the central point lights up If the code already exists in...

Page 14: ...lay Door2 Door1 ExitPB Door2 ExitPB Power supply Diameter6 10 500mmaxlength Diameter6 10 100mmaxlength Diameter6 10 100mmaxlength Notconnected Door 1 and Door 2 controlled by the proximity key or the...

Page 15: ...ode at least one of the points on the left or the right of the display lights up To modify the authorisation press Present the proximity key on the reading zone on the right of the display After the c...

Page 16: ...now the existing password Enter programming mode Display function F1 using and keys Hold the key pressed down for 1 second the display flashes once and the password is deleted 2 Function F2 State of P...

Page 17: ...ys then validate using the key If the memory is a 2KS 500 keys version a message DIF advise that only the 500 first keys will be copied The display indicates 1 2 which means a copy of the main memory...

Page 18: ...2V DC Fail Secure Lock In case of alternative current power supply use a variable resistor instead of a diode Use a power supply suitable for the fail safe lock We strongly recommend using a separate...

Page 19: ...ply to keep the door locked For instance in the event of power failure the door would become unlocked Controlling a fail safe lock Door 1 Terminal n 8 common Terminal n 9 idle Door 2 Terminal n 16 com...

Reviews: