DOOR 1: controlled by channel 1
DOOR 2: controlled by channel 2
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
L+ L- LD
Not used
C NC NO L+ L- LD
Not used
C NC NO
Relay
Door 1
Relay
Door 2
Exit PB
Exit PB
Power
supply
+ -
RF Antenna 433MHz
in option
Coax cable
50Ohms 10m max
Diameter 6/10
500m max length
Power supply
DC power supply: 12V DC - 0.4 A (acceptable range: 10.8V to 22V)
AC power supply: 12V AC (12V in nominal value and maximum power of 5 VA)
Door 1 controlled by channel 1
Door 2 controlled by channel 2
1
To connect a Fail-Safe or a Fail secure Lock, please refer to page 18
8
50-000-611 DOC TRANSIT GB FDI
C