4.2 LED INDICATORS
The control panel is equipped with 12 LEDs which notify alarms, faults and exclusions. For further information, please refer to the
programming manual.
Icon
Name
Colour
Function
AC / BATTERY
GREEN
Steady ON: the control panel is power supplied through
the AC mains.
Blinking: the control panel is power supplied through
the batteries.
Steady OFF: the command and control module is faulty.
ALARM
RED
Steady ON: the control panel is in alarm condition with
siren output ON.
GENERAL
EXCLUSION
YELLOW
Steady ON: at least one exclusion is present.
This indicator provides a cumulative notification of
exclusions.
GENERAL FAULT
YELLOW
Steady ON: at least one fault is present.
This indicator provides a cumulative notification of
faults. Further details on the fault type are provided
through the display or dedicated LEDs.
SYSTEM FAULT
YELLOW
Steady ON: a system fault is present.
Usually, when this LED is turned ON the CPU stops
working properly because of an hardware problem (e.g.,
some peripheral stops working as expected) or a
serious malfunctioning of the program.
BATTERY FAULT
YELLOW
Steady ON: a fault or a malfunctioning of the batteries
of the control panel occurs.
BATTERY CHARGER
FAULT
YELLOW
Steady ON: a fault to the battery charger has occurred.
FUSE FAULT
YELLOW
Steady ON: a fault to a fuse has occurred.
SIREN FAULT
YELLOW
Steady ON: the line connected to a siren output is in
fault (because of missing end of line resistor, short
circuit or fuse fault).
GROUND
DISPERSION
YELLOW
Steady ON: an electric ground dispersion is present.
SIREN EXCLUDED
YELLOW
Steady ON: at least one siren output is excluded.
TEST
YELLOW
Steady ON: a zone test is active.