826
button in response to a call from a main entrance panel will release
the lock connected to the main entrance panel from which the
call was made, as well as the lock connected to the secondary
entrance panel associated with the apartment station concerned. In
the second case, pressing the apartment station door lock release
button in response to a call from a main entrance panel will release
only the lock connected to the main entrance panel with digitizer
from which the call was made: a second call will have to be made
from the secondary entrance panel before the lock connected to it
can be released.
STEP 6 - Password
This step is not used. Direct door lock release via special codes is not
possible in systems equipped with digitizers.
BUSY SIGNAL VOLUME ADJUSTMENT
The digitizer generates a busy signal when a call is in progress from
another digitizer, entrance module or guard door switchboard station.
Volume of this signal can be adjusted by means of the trimmer located
adjacent to the jumpers.
NOTE:
In situations a) or b) as described above, where multiple
digitizers are connected directly to each other for system
expansion, all trimmers must be set to the same volume.
SPEAKER
AND
MICROPHONE
VOLUME
ADJUSTMENT FOR SPEAKER UNIT
Adjust speaker and microphone volume for the entrance panel speaker
unit associated with the digitizer as directed in the instruction sheet.
NOTICE:
The speaker unit must be set up to operate with electronic call
tone signaling doorphones and monitors (terminal 1A) or with
conventional buzzer type apartment station equipment (terminal 1).
REPLACING AN OLD DIGITIZER
•
STEP 1:
−
Install jumper PT3 P/S if digitizer is confi gured for
use at a main entrance panel
−
Remove the jumper is digitizer is confi gured for use
at a secondary entrance panel.
•
STEP 2:
−
Install jumper PT1 in position 1.
•
STEP 3:
−
See instructions, noting that fi rst-generation systems
cannot be used with confi guration c), TYPE 2.
•
STEP 4:
See instructions.
•
STEP 5:
See instructions.
•
STEP 6:
See instructions.
Systems with earlier-model digitizers can operate only with conventional
type apartment station equipment. Terminal 1 on speaker unit must
thus be connected rather than terminal 1 A.
OPERATION
An acoustic signal is generated each time a call key on the entrance
panel is depressed.
When a key on the entrance panel connected to the digitizer is
actuated, the ringer at the called apartment station will be activated for
the entire period that the key is held down. A protection feature will
interrupt ringing if the key is held down for more than 5 seconds).
Code numbers assigned via the two selector switches will depend on
two factors:
•
Whether the digitizer is confi gured for use at a main or secondary
entrance panel;
•
If it is confi gured for a secondary entrance panel, on the installation
type.
Code numbers to be assigned to digitizers for each type of application
are shown on the installation diagrams.
STEP 4 - Engaged time (Jumper PT2: 10”/20”/40”)
This parameter is used in systems with two or more main entrance
panels featuring automatic switching between them. In such situations,
it is necessary to ensure that a conversation originating from an
entrance panel will not be cut off for a certain minimum duration, which
may be programmed from 10 to 40 seconds. During this programmed
minimum duration, which is called the “engaged time”, calls cannot be
made from the other entrance panels, where an intermittent warning
tone will be emitted to indicate that they cannot be used unit the
programmed engaged time has ended.
Once the programmed engaged time has ended, an ongoing call will be
interrupted immediately if a call is made from another entrance panel.
The engaged time parameter is also used for secondary entrance
panels. When a main entrance panel or guard door switchboard station
makes a call to an apartment station which is physically connected
to the riser cable associated with a given secondary entrance panel,
it will not be possible to make calls from this panel for the entire
programmed engaged time.
•
Move the jumper to 10” to establish an engaged time of 10 seconds
•
Move the jumper to 20” to establish an engaged time of 20 seconds.
•
Move the jumper to 40” to establish an engaged time of 40 seconds.
It is advisable to confi gure all entrance panels in the system for the
same engaged time.
STEP 5 - Electric lock management (Jumper PT4)
•
Position the jumper to confi gure UNRESTRICTED DOOR LOCK
RELEASE:
•
If the digitizer is confi gured for use at a main entrance panel, the
electric door lock connected to it will be released at any time that
the door lock release button is pressed at any apartment station.
•
If the digitizer is confi gured for use at a secondary entrance panel,
the electric door lock connected to it will be released at any time
that the door lock release button is pressed at any apartment station
connected to its riser cable.
•
Remove the jumper to confi gure DOOR LOCK RELEASE PROTECTED
BY PRIVACY FEATURE. This means that the electric door lock
connected to the digitizer module will be released only when the door
lock release button is pressed at an apartment station that has been
called from the entrance panel with the digitizer in question. In
this case, the door lock can be released for a period at least equal to
the programmed engaged time but not exceeding 10 minutes.
The criterion selected for electric lock management is essential to
correct system operation.
STRICTLY
ADHERE
TO
THE
INSTRUCTIONS
BELOW:
CONFIGURATIONS OTHER THAN THOSE DESCRIBED CANNOT
BE USED.
•
In installations with a single main entrance panel and no secondary
entrance panels, the digitizer may be confi gured either for
UNRESTRICTED DOOR LOCK RELEASE or for DOOR LOCK
RELEASE PROTECTED BY PRIVACY FEATURE.
•
In type b) installations with two or more main entrance panels
with automatic switching between them, it is essential that all
digitizers be confi gured for DOOR LOCK RELEASE PROTECTED
BY PRIVACY FEATURE.
•
In type c) installations where digitizers are used at secondary
entrance panels, it is essential that the main entrance panel or
panels be programmed for DOOR LOCK RELEASE PROTECTED
BY PRIVACY FEATURE.
The secondary entrance panel(s) can be programmed either for
UNRESTRICTED DOOR LOCK RELEASE or for DOOR LOCK
RELEASE PROTECTED BY PRIVACY FEATURE.
In the fi rst case, pressing the apartment station door lock release
16-PUSHBUTTON DIGITIZER Ref. 826/16
OPERATION
1
6
-P
U
S
H
BU
TT
ON
DIGI
T
IZ
E
RR
e
f.
826
/1
6
OU
T
DOO
R
ST
A
T
ION
E
Q
UI
P
M
E
N
T
1
- 36
MT124-019
Summary of Contents for 826 DIGITAL CALL SYSTEM
Page 1: ...Model 826 DIGITAL CALL SYSTEM http www urmetdomus com e mail info urmetdomus it MT 124 019 ...
Page 9: ...1 1 MT124 019 Section 1 PRODUCT ...
Page 79: ...Section 2 INSTALLATION DIAGRAM 2 1 MT124 019 ...
Page 80: ...CONTENTS Model 826 DIGITAL CALL SYSTEM 2 2 MT124 019 ...
Page 83: ...826 PARALLEL CONNECTIONS 2 5 MT124 019 ...
Page 89: ...826 DOORPHONE SYSTEMS 2 11 MT124 019 ...
Page 103: ...826 DOORPHONE SYSTEMS WITH GUARD DOOR SWITCHBOARD STATION 2 25 MT124 019 ...
Page 111: ...826 VIDEO DOORPHONE SYSTEMS 2 33 MT124 019 ...
Page 118: ......