![urmet domus 826 DIGITAL CALL SYSTEM Manual Download Page 43](http://html1.mh-extra.com/html/urmet-domus/826-digital-call-system/826-digital-call-system_manual_1062556043.webp)
826
MEMORANDUM LABEL
STEP 3 - Entrance panel number (Selector switches “M” and “C”)
The selector switches (3), designated “M” and “C” perform a dual
function:
•
They establish a correspondence between the call key depressed at
the entrance panel and the code which the digitizer transmits as a
result. By contrast with systems featuring entrance modules, where
the keypad can be used to transmit any call code, the digitizer can
only transmit 16 call codes, i.e., one per call key. For the sake of
convenience, these codes are consecutive. Thus, selector switches
“M” and “C” are used to establish the fi rst (“MC01”) of these sixteen
codes, which will consequently be between “MC01” and “MC16”
•
They are used to assign an identifi cation number to the digitizer.
This number will be as follows:
•
“MCO” in systems where the digitizer is used at a main entrance
panel.
•
”M” in TYPE 1 systems where the digitizer is used at a secondary
entrance panel.
•
“MC” in TYPE 2 systems where the digitizer is used at a secondary
entrance panel.
This type of connection is possible if the digitizer is used in a secondary
entrance panel, but only in installation TYPE 1 and only if there are
no more than 10 apartment stations per entrance panel. However, it is
not recommended for the following reason:
•
Using a digitizer is not economical if more than 16 call keys must be
managed: it is better to use an entrance module.
Sixteen consecutive call codes can be stored in the digitizer memory.
The code which will be sent when a call key is pressed will thus be
between “MC01” and “MC16”, where “M” is the digit set by means of
the fi rst selector switch and “C” is the digit set by means of the second
selector switch. Selector switches must be positioned in accordance
with the system’s installation TYPE.
EXPANDABILITY
Where the digitizer is used during renovation of systems with up to two
main outdoor stations, the existing entrance panels may have more
than 16 call keys. In such cases, additional digitizers can be installed
side by side and connected to handle further apartment stations in
multiples of 16 (32, 48, 64 ... ).
To do so, digitizers must be connected as shown in the fi gure below.
Note that terminals “U” and “E” on adjacent digitizers are connected in
loop-through confi guration, and that all terminals “INI” are connected
in parallel. Strictly adhere to this connection confi guration to ensure
that digitizers and the system will operate correctly.
16-PUSHBUTTON DIGITIZER Ref. 826/16
EXPANDABILITY - CONFIGURATION
16-PUSHBUTTON DIGITIZER Ref. 826/16
PUSH BUTTON PANEL AND
LOUDSPEAKING UNIT
Lock
release
Electric lock
M Migliaia
/
Thousands
/ Milliers
C Centinaia
/
Hundreds
/ Centaines
Impostazione modo di impianto
PT1
Selection of the system
Sélection type d'installation
Tempo occupato
PT2
Call module "busy" period
Temps module d'appel occupé
Identificazione posto chiamata
PT3
Call module identification
Identification du module d'appel
Servizio apriporta
PT4
Lock opening
Ouverture serrure
Regolazione segnale acustico
P1
Acoustic level adjustement
Réglage niveau acoustique
PREDISPOSIZIONI /
ARRANGEMENTS
PREDISPOSITIONS
CODICI /
CODES
CODES
1
2
10"
20"
40"
P
S
C
M
Libera /
At any time / A tout moment
Solo se chiamati /
Only when called /
Seulement si appelés
MAX
MIN
P / S
CONFIGURATION
Prior to installation, the digitizer must be confi gured for the type of
service to be performed.
Confi guration settings are established by means of the selector
switches and jumpers located on the upper left of the electronic circuit
board.
NOTICE
To ensure that system maintenance can be effi ciently performed,
it is ESSENTIAL that the memorandum label be fi lled out at the
time the digitizer is confi gured for service.
Turn off power supply to the digitizer and proceed as follows:
STEP 1 - Type of entrance panel (Jumper PT3: M/S)
•
Install the jumper to confi gure the digitizer for use at a main entrance
panel.
•
Remove the jumper to confi gure the digitizer for use at a main
entrance panel.
STEP 2 - Installation type (Jumper PT1: 112)
•
Move jumper to position 1 to confi gure the digitizer for installation
Type 1.
•
Move jumper to position 2 to confi gure the digitizer for installation
Type 2.
NOTE:
Digitizers cannot be used with installation Type 3.
1
6
-PUS
H
BUTTON D
IG
IT
IZ
ER
Re
f.
826
/1
6
OUTDOOR STAT
ION E
Q
U
IPMENT
1
- 35
MT124-019
Summary of Contents for 826 DIGITAL CALL SYSTEM
Page 1: ...Model 826 DIGITAL CALL SYSTEM http www urmetdomus com e mail info urmetdomus it MT 124 019 ...
Page 9: ...1 1 MT124 019 Section 1 PRODUCT ...
Page 79: ...Section 2 INSTALLATION DIAGRAM 2 1 MT124 019 ...
Page 80: ...CONTENTS Model 826 DIGITAL CALL SYSTEM 2 2 MT124 019 ...
Page 83: ...826 PARALLEL CONNECTIONS 2 5 MT124 019 ...
Page 89: ...826 DOORPHONE SYSTEMS 2 11 MT124 019 ...
Page 103: ...826 DOORPHONE SYSTEMS WITH GUARD DOOR SWITCHBOARD STATION 2 25 MT124 019 ...
Page 111: ...826 VIDEO DOORPHONE SYSTEMS 2 33 MT124 019 ...
Page 118: ......