826
•
Enter “1” to program engaged time as 10 seconds.
•
Enter “2” to program engaged time as 20 seconds.
•
Enter “3” to program engaged time as 30 seconds.
•
Enter “4” to program engaged time as 40 seconds.
It is advisable to program all entrance panels in the system for the
same engaged time.
Press the call button
to go on to the fi fth step.
STEP 5 - Electric lock management
Enter “0” to confi gure UNRESTRICTED DOOR LOCK RELEASE:
•
If the module is confi gured as a main entrance panel, the electric
door lock connected to it will be released at any time that the door
lock release button is pressed at any apartment station.
•
If the module is confi gured as a secondary entrance panel, the
electric door lock connected to it will be released at any time that
the door lock release button is pressed at any apartment station
connected to its riser cable.
Enter “1” to confi gure DOOR LOCK RELEASE PROTECTED BY
PRIVACY FEATURE. This means that the electric door lock connected
to the entrance module will be released only when the door lock
release button is pressed at an apartment station that has been
called from the entrance module in question. In this case, the door
lock can be released for a period at least equal to the programmed
engaged time but not exceeding 10 minutes.
The criterion selected for electric lock management is essential to
correct system operation.
STRICTLY
ADHERE
TO
THE
INSTRUCTIONS
BELOW:
CONFIGURATIONS OTHER THAN THOSE DESCRIBED CANNOT
BE USED.
•
In installations with a single main entrance panel and no secondary
entrance panels, the entrance module may be confi gured either
for UNRESTRICTED DOOR LOCK RELEASE or for DOOR LOCK
RELEASE PROTECTED BY PRIVACY FEATURE.
•
In installations with two or more main entrance panels with automatic
switching between them, it is essential that all entrance modules be
confi gured for DOOR LOCK RELEASE PROTECTED BY PRIVACY
FEATURE.
•
In installations with at least one secondary entrance panel, it is
essential that the main entrance panel or panels be programmed for
DOOR LOCK RELEASE PROTECTED BY PRIVACY FEATURE.
The secondary entrance panel(s) can be programmed either for
UNRESTRICTED DOOR LOCK RELEASE or for DOOR LOCK
RELEASE PROTECTED BY PRIVACY FEATURE.
In the fi rst case, pressing the apartment station door lock release
button in response to a call from a main entrance panel will release
the lock connected to the main entrance panel from which the call
was made, as well as the lock connected to the secondary entrance
panel associated with the apartment station concerned. In the second
case, pressing the apartment station door lock release button in
response to a call from a main entrance panel will release only
the lock connected to the main entrance panel from which the call
was made: a second call will have to be made from the secondary
entrance panel before the lock connected to it can be released.
Press the call button
to go on to the fi fth step.
STEP 6 - Password
Door locks can also be released by entering a special code via the
entrance module keypad. Up to eight such codes can be stored in the
entrance module’s memory. These codes are NOT stored in memory
during this programming step, as this can be accomplished at any time
by using the keypad. It is thus not necessary to open the entrance
module for this purpose. However, a password must be used to access
the door lock release code programming procedure, thus ensuring that
only the installer or other authorized persons can change the door
lock release codes. The sixth programming step is used to store this
password in memory.
The password consists of four digits:
•
Numbers between “0001” and “9999” can be assigned.
•
Entering the number “0000” as the password will automatically
disable the feature: it will not be possible to use door lock release
codes or enter new ones.
Press the call button
to exit from the programming procedure. The
LED located at the rear of the entrance module will go off.
DOOR LOCK RELEASE CODE ENTRY
One the entrance module has been closed in the fl ush mounting back
box, door lock release codes can be entered in its memory.
Codes can be entered only if the password established during
programming step 6 is known.
To access the procedure, carry out the following operations:
•
Password recognition
Press the “0” key twice: the display will go black and the numeric
keypad will be disabled for 4 seconds. At the end of this period,
the entrance module will beep to indicate that the fi rst digit in the
password can now be entered.
The fi rst digit must be entered within 4 seconds of the beep. If it is
not, the entrance module will return to stand-by status.
After the fi rst digit has been entered, a dash will be shown on
the display: this is because password digits are not displayed for
security reasons.
The keypad will again be disabled for 4 seconds. The entrance
module will then beep to indicate that second digit in the password
can be entered (again, the digit must be entered within 4 seconds of
the beep).
Continue with the same procedure until all four digits in the password
have been entered.
•
Code entry
Once all four digits in the password have been entered and
recognized by the entrance module, the display will show the fi rst
door lock release code in memory. If the entrance module does not
recognize the password, it will return to stand-by status.
•
Enter the desired code, which may consist of any digit between
“0001” and “9999”.
•
To delete the code, overwrite it as “0000”.
Press the call button
to go on to the second door lock release
code. If a mistake is made in entering the code, press the “X” key to
delete the error and return the former code to the display.
To read existing codes and confi rm them without change, press the
call button
again.
After entering the eighth door lock release code, press the call
button
. The entrance module will store all entered codes in
memory, returning to stand-by status after a few seconds. The
module is now ready for normal operation.
Example: Password entered during step 6 of the programming
procedure: 5 2 9 4.
Proceed as follows:
Enter “00” and wait 4 seconds for the beep.
Enter “5” and wait 4 seconds for the beep.
Enter “2” and wait 4 seconds for the beep.
Enter “9” and wait 4 seconds for the beep.
Enter “4” . The password is now complete.
ENTRANCE MODULE ON KOMBI CHASSIS Ref. 826/65
PROGRAMMING
E
N
T
RANC
E
M
ODUL
E
ON
K
O
M
BI
CHA
SS
IS
R
e
f.
826
/6
5
OU
T
DOOR
ST
A
T
ION
E
Q
UI
P
M
E
N
T
1
- 28
MT124-019
Summary of Contents for 826 DIGITAL CALL SYSTEM
Page 1: ...Model 826 DIGITAL CALL SYSTEM http www urmetdomus com e mail info urmetdomus it MT 124 019 ...
Page 9: ...1 1 MT124 019 Section 1 PRODUCT ...
Page 79: ...Section 2 INSTALLATION DIAGRAM 2 1 MT124 019 ...
Page 80: ...CONTENTS Model 826 DIGITAL CALL SYSTEM 2 2 MT124 019 ...
Page 83: ...826 PARALLEL CONNECTIONS 2 5 MT124 019 ...
Page 89: ...826 DOORPHONE SYSTEMS 2 11 MT124 019 ...
Page 103: ...826 DOORPHONE SYSTEMS WITH GUARD DOOR SWITCHBOARD STATION 2 25 MT124 019 ...
Page 111: ...826 VIDEO DOORPHONE SYSTEMS 2 33 MT124 019 ...
Page 118: ......