DS1067-063D
112
LBT20064
8.2
1067/032A CONTROL PANEL
Nominal power voltage ....................................................................................................... 230 Vac +10% -15% 50/60 Hz
Max absorption power at 230 V (1061/515) .............................................................................................................. 600 mA
1061/515 power output nominal voltage - Type A power supply ............................................................................. 14.4 Vdc
Max current deliverable 1061/515 power supply ........................................................................................................... 1.5 A
Ripple max 1061/515 ....................................................................................................................... 100 mV p.p. with I = 1A
Control panel operating voltage .............................................................................................................. 10.5 Vdc to 16 Vdc
Overload protection tripping current ........................................................................................................................... 16 Vdc
Nominal current absorbed by control panel with 1067/002A board at 12 Vdc
(with relays energised, default condition) .................................................................. 85 mA stand-by with balanced inputs
(with relays de-energised) ........................................................................................................ 65 mA with balanced inputs
Installable battery ............................................................................................................................................. 12 V
– 7.2 Ah
Nominal voltage of battery charger (
Note 1
) ........................................................................................................... 13.8 Vdc
Max current supplied to charge battery ..................................................................................................................... 350 mA
Max time for recharging battery to 80%................................................................................................................... 24 hours
Battery flat threshold ................................................................................................................................................... 11.5 V
Battery release threshold ............................................................................................................................................ 10.5 V
Automatic test battery................................................................................................................ every 24 hours (with mains)
Max current for external devices (keypads, sensors, sirens) taken from +, +V1, +V2 terminals:
Degree 3
– with ATS4 dialler and 60 hour autonomy ......................................................... CONFIGURATION NOT POSSIBLE
Degree 3
– with ATS4 dialler and 30-hour autonomy (
Note 2
) ........................................................................................ 135 mA
(total 220 mA, of which 85 mA for the control panel with 1067/002A)
Degree 2
– with ATS2 dialler and 12 hour autonomy ...................................................................................................... 365 mA
(total 450 mA, of which 85 mA for the control panel with 1067/002A)
Nominal voltage on the +SR terminal (
Note 3
) ........................................................................................................ 14.4 Vdc
Max current deliverable from the +SR terminal ................................................................ 200 mA (with overload protection)
Nominal voltage on the + terminal ................................................................................................................ 13.8 Vdc ±1,5%
Max current deliverable from + terminal ............................................................................. 1100 mA (with overload protection)
Nominal voltage on the +V1 terminal ........................................................................................................... 13.8 Vdc ±1,5%
Max. current deliverable from +V1 terminal ...................................................................... 750 mA (with overload protection)
Nominal voltage on the +V2 terminal ........................................................................................................... 13.8 Vdc ±1,5%
Max total current deliverable from the +V2 terminals ....................................................... 750 mA (with overload protection)
Ripple max on oSR + +V1 +V2 with flat battery............................................................................ 100 mV (0,7%)
Max current and voltage of relay contact switch of outputs U1 and U2 ........................................ 1 A
– 24 Vdc with resistive load
Max current deliverable from electric output U3 ........................................................................................................ 100 mA
Max current deliverable from electric outputs U4, U5, U6 ........................................................................................... 10 mA
Tamperproof switch ........................................................................................................................................... 1 A
– 24 Vdc
Max total length of control panel-peripheral serial Bus line ......................................................................................... 400 m
Max length of the audio line (audio bus) ............................................................................... 300 m with twin telephone line
Max length of the connection between each sensor or actuator and the control panel ............................................... 500 m
Max length of the connection between a fast sensor (roller, shock,...) and the control panel ............................................ 100 m
Max number possible code combinations ..................................................................................... from 10.000 to 1.000.000
Number of possible combinations of electronic keys .............................................................................. more than 1099 billion
Number of possible combinations of proximity keys ..................................................................................... more than 4 billion
Programmable time entry ............................................................................................................................. 5 s to 5 minutes
Programmable exit entry .............................................................................................................................. 5 s to 5 minutes
Programmable alarm time ...........................................................................................30 s ÷ 15 minutes (default 3 minutes)
Programmable tamper alarm time ...............................................................................30 s ÷ 15 minutes (default 3 minutes)
Failure signal ................................................................................... optical (LED) and electric for control panel battery low,
fuses, low power supply expansion boards
Type of memory for programming, Events log, and diagnose log maintenance ................................................... Data Flash
Certified working temperature (EN50131
– Environmental class II, general internal) ................................... -10°C to +40°C
Average relative humidity during operation .................................................................................................................... 75%
Storage temperature ..................................................................................................................................... -20°C to +60°C
Degree of protection of casing ............................................................................................................................. IP40 / IK06
Dimensions (W x H x D) .......................................................................................................................... 338 x 240 x 90 mm
Weight (without battery) ............................................................................................................................................. 1400 g
For further information, see also paragraph 1.2.3
Note 1
): If the battery is not connected to the terminals of the connection cables, (red and black Faston) there is no power;
Note 2
): remotely assisted system with guaranteed intervention in case of lack of power;
Note 3
): in case of blackout, the
+SR
does not supply voltage.