8.14 1067/092 SUPPLEMENTARY POWER UNIT WITH REPEATER
Section - BUS IN
Nominal power voltage ......................................................................................... 13.8 Vdc (supplied by control panel BUS)
Expansion operating voltage ........................................................................................................................ 9 Vdc to 15 Vdc
Nominal current absorbed at 12 Vdc
(with relays energised, default condition) .................................................................. 50 mA stand-by with balanced inputs
(with relays de-energised) ........................................................................................................ 40 mA with balanced inputs
Nominal voltage on the +V1 terminal ................................................................... 13.2 Vdc (supplied by control panel BUS)
Max current deliverable from +V1 terminal ....................................................................... 500 mA (with overload protection)
Nominal voltage on the +V2 terminal ................................................................... 13.2 Vdc (supplied by control panel BUS)
Max total current deliverable from the +V2 terminals ....................................................... 500 mA (with overload protection)
Max current and voltage of relay contact switch of outputs U1 ............................................ 1 A
– 24 Vdc with resistive load
Max current deliverable from electric outputs U2 and U3 ............................................................................................ 10 mA
Max total length of control panel-peripheral serial Bus line (primary BUS).................................................................. 400 m
Max. connection length between each sensor or actuator and expansion .................................................................. 500 m
Max length of the connection between a fast sensor (roller, shock, ...) and the expansion ......................................... 100 m
Supplementary power section and BUS OUT
Nominal power voltage ........................................................................................................ 230 Vac +10% -15% 50/60 Hz
Max absorption power at 230 V (MW RS-50-15) ....................................................................................................... 800 mA
MW RS-50-15 power output nominal voltage - Type A power supply ..................................................................... 14.4 Vdc
Max. deliverable current
:.………………………………………………………………………………………………………...3.4 A
Ripple max. MW RS-50-
15………………………………………………………………………………120 mV p.p. with I = 3.4 A
Operating voltage of the electronic power supply/repeater .......................................................................... 9 Vdc to 15 Vdc
Max current absorbed by the electronic power supply/repeater ................................................................................ 100 mA
Installable battery .............................................................................................................................................. 12 V - 18 Ah
Nominal voltage of battery charger
note 1
) ...................................................................................... 13.8 Vdc
Max. current supply to charge battery ....................................................................................................................... 500 mA
Max time for recharging battery to 80%................................................................................................................... 48 hours
Battery flat threshold ................................................................................................................................................... 11.5 V
Battery release threshold ............................................................................................................................................ 10.5 V
Automatic test battery (controlled by control panel) .................................................................. every 24 hours (with mains)
Max current for external devices (keypads, sensors, sirens) taken from + (BUS OUT), +, + terminals
Degree 2
– with ATS2 dialler and 12 hour autonomy ........................................................................................... 1050 mA
(total 1150 mA, of which 100 mA for electronics)
Nominal voltage on the +SR terminal
note 2
) .................................................................................... 14.4 Vdc
Max current deliverable from the +SR terminal ................................................................ 200 mA (with overload protection)
Nominal voltage on the + (BUS OUT) terminal ............................................................................................ 13.8 Vdc ±1.5%
Max. current deliverable from + (BUS OUT) terminal ........................................................... 1100 mA (with overload protection)
Nominal voltage on the + (BUS OUT) terminal ............................................................................................ 13.8 Vdc ±1.5%
Max. total current deliverable from +V terminals ............................................... 750 mA ciascuno (with overload protection)
Ripple max on oSR + + with flat battery ........................................................................................ 120 mV (0,9%)
Max. total length of serial power supply-peripheral BUS OUT line (secondary BUS) .................................................. 400 m
Certified operating temperature (EN50131
– Environmental class II, internal general) .................................. -10°C ÷ +40°C
Average relative humidity during operation .................................................................................................................... 75%
Storage temperature ...................................................................................................................................... -20°C ÷ +60°C
Degree of protection of casing ............................................................................................................................. IP40 / IK02
Dimensions (W x H x D) .......................................................................................................................... 435 x 320 x 93 mm
Weight (without battery) ............................................................................................................................................. 5600 g
Note 1
)
:
if the battery is not connected to the head of the teBT -BT there is no power.
Note 2
)
:
in case of blackout, the +SR
does not supply voltage.