Page 3-3
Maintenance
3.4 - UpRight Connectors
X Series Work Platform
M
ALE
C
ONNECTOR
(P
LUG
)
1. Disconnect the male connector (plug) from the female connector (receptacle).
2. Using the flat end of the Removal Tool (or flat blade screwdriver), pry the Locking Wedge
from the Male Connector. Care should be taken that the Silicon Gasket is not damaged dur-
ing this procedure.
3. Check all parts for damage. Replace all parts which are damaged or worn.
4. Replace or recrimp the wires and contacts. Refer to “Crimping” procedure.
F
EMALE
C
ONNECTOR
(R
ECEPTACLE
)
1. Disconnect the male connector (plug) from the female connector (receptacle).
2. Using the notched end of the Removal Tool (or a wire hook), pull the Locking Wedge from
the Female Connector.
3. Check all parts for damage. Replace all parts which are damaged or worn.
4. Replace or recrimp the wires and contacts. Refer to “Crimping” procedure.
R
ELEASING
L
OCKING
F
INGERS
Figure 3-3: Locking Finger, UpRight Connector
1. The Locking Fingers can be released
following the removal of the Locking
Wedge of either the male or female
connector.
2. Use the removal tool (or flat bladed
screwdriver) to push the Locking Fin-
gers aside. This will release the grip
on the contact.
3. Pull the wire and contact out of the
connector.
C
RIMPING
NOTE:
Complete crimping instructions are included in each Field Kit.
1. Strip ¼” (6 mm) from the wire.
2. Insert the contact into the crimping tool.
3. Insert the stripped wire into the contact. Copper strands should be visible in the bleed hole
of the contact, and no copper strands should be loose (outside) of the contact barrel.
4. Completely close the handles of the crimping tool. Release the handles of the crimping tool
and remove the crimped contact.
5. Inspect the crimped contact to ensure that all strands are secure in the crimp barrel.
R
EMOVING
C
ONTACT
FROM
H
EAVY
D
UTY
P
LUG
Figure 3-4: Heavy Duty UpRight Connector
1. Slip the removal tool along the wire to
be replaced.
2. Push the removal tool into the connec-
tor until the contact is released.
3. Pull the wire and contact out of the
plug.
060571-005
Summary of Contents for X Series
Page 1: ...060571 005 ...
Page 54: ...Page 3 26 Maintenance 3 19 Torque Specifications X Series Work Platform NOTES 060571 005 ...
Page 62: ...Page 4 8 Troubleshooting 4 6 Electric X Series Work Platform NOTES 060571 005 ...
Page 79: ...Page 6 3 Illustrated Parts Breakdown 6 1 Introduction X Series Work Platform NOTES 060571 005 ...
Page 125: ...Page 6 49 Illustrated Parts Breakdown 6 1 Power Module X Series Work Platform 060571 005 ...
Page 127: ...Page 6 51 Illustrated Parts Breakdown 6 1 Control Module X Series Work Platform 060571 005 ...
Page 135: ...Page 6 59 Illustrated Parts Breakdown 6 1 Hose Kit X20N X Series Work Platform 060571 005 ...
Page 139: ...Page 6 63 Illustrated Parts Breakdown 6 1 Hose Kit X31N X Series Work Platform 060571 005 ...
Page 147: ...Page 6 71 Illustrated Parts Breakdown 6 1 Label Kit X20N X Series Work Platform 060571 005 ...
Page 149: ...Page 6 73 Illustrated Parts Breakdown 6 1 Label Kit X20W X Series Work Platform 060571 005 ...
Page 151: ...Page 6 75 Illustrated Parts Breakdown 6 1 Label Kit X26N X Series Work Platform 060571 005 ...
Page 153: ...Page 6 77 Illustrated Parts Breakdown 6 1 Label Kit X31N X Series Work Platform 060571 005 ...
Page 163: ...060571 005 ...