LX31/41 Electric Work Platform 4-7
T
RO U B L E S H O O T I N G
Section
4.6
When BATTV, MOTORV, MOTORA and TEMPC are
selected, the controller shows their values. When
BATTV is selected and the "+" button is held in, the
highest voltage that the MOS90 has recorded will be
displayed. When TEMPC is selected and the "+" but-
ton is held in, the highest temperature that the
MOS90 has recorded will be displayed. The "-" button
will display the lowest values.
When the MOS90 is first powered up, the recorded
minutes of run time is displayed. The "+" button dis-
plays thousands of hours and the "-" button displays
hundreds of hours. When the MOS90 is pulsing
(being used) run time is being incremented and
stored. The "dot" in the time display is blinking when
MOS90 is being used, steady when idle.
4.6 C
ALIBRATOR
S
ETTINGS
4.7 U
PRIGHT
T
RACTION
C
ONTROLLER
DISPLAY
Table 4-2: Calibrator Settings
LED
Function
Unit
Setting
Comments
1
MOS90 Maximum Amp. Capacity
Amps
600
Adjustable from 50
amps to 600 amps
2
Acceleration Delay
Seconds
1.0
Adjustable from 1.0
sec to 3.0 sec.
3
Deceleration Delay
Seconds
0.5
Adjustable from 0.5
sec. to 3.0 sec.
4
Traction Creep
%
0
Adjustable from 0% to
10%
5
Max. allowed Speed
%
65
Adjustable from 5% to
100%
6
Cutback Speed 1
%
20
Adjustable from 5% to
25%
7
Cutback Speed 2
%
75
Adjustable from 20%
to 75%
8
Pump Current limit
Amps
270
Adjustable from 50
amps to 600 amps
9
Cutback1 Plug Current
Amps
400
Adjustable from 180
amps to 750 amps
10
CSC Proportional Gain
1
30
Adjustable from 1 to
100
11
CSC Integral Gain
1
20
Adjustable from 1 to
100
12
Low Voltage Cutout
Volts
25
Adjustable from 25
Volts to 40 Volts
13
Pump Acceleration Delay
Seconds
2.0
Adjustable from 1.0 to
3.0
14
Pump Creep
%
0%
Adjustable from 0% to
30%
Table 4-3: Calibrator Display
Sequence No.
Test
Display
Input #
-
Acc. Input
0-100%
14
1
Forward
CL/OP
8
2
Reverse
CL/OP
11
3
Tach Input
0-100%
12
4
Elev. Pos.
CL=Clpsd.
4
OP=Lifted
5
Tilt Switch
CL=Level
7
OP=Tilt
6
Pump Switch
CL= Pump
16
OP=Trac.
7
Act. Direction
OP=FWD
2
Tacho Output
CL=REV
8
High/Low Speed
CL=High
13
OP=Low
9
Direction Flag
OP=No Dr.
-
CL=Drv actv.
10
First Error Latch
Value=
0-255
Flash Code
NOTE: CL = Switch Closed
OP = Switch Open
Summary of Contents for LX31
Page 1: ......
Page 2: ......
Page 4: ......
Page 6: ...ii LX31 41 Electric Work Platform FORWARD NOTES ...
Page 24: ...2 12 LX13 41 Electric Work Platform MACHINE PREPARATION OPERATION Section 2 10 NOTES ...
Page 49: ...LX31 41 Electric Work Platform 3 25 MAINTENANCE Section 3 19 NOTES ...
Page 66: ...4 16 LX31 41 Electric Work Platform TROUBLESHOOTING Section 4 9 ...
Page 74: ...5 8 LX31 41 Electric Work Platform SCHEMATICS Section 5 4 ...
Page 115: ...LX31 41 Electric Work Platform 6 41 ILLUSTRATED PARTS BREAKDOWN Section 6 1 ...
Page 117: ...LX31 41 Electric Work Platform 6 43 ILLUSTRATED PARTS BREAKDOWN Section 6 1 ...
Page 118: ...6 44 LX31 41 Electric Work Platform ILLUSTRATED PARTS BREAKDOWN Section 6 1 NOTES ...
Page 119: ......