background image

Read Instructions Before Installing

Plastic Opto-Matic Oilers

Spirit 

Level

Fig. 2

Spirit 

Level

Fig. 3

TRICO CORPORATION

 1235 Hickory St., Pewaukee, WI 53072  Phone: (262) 691-9336

www.tricocorp.com

61402     02/19

RESERVOIR FOR

4 oz. (120 ml.)Oilers - 20283R

All types and sizes - 20315R

UPPER CASTING WITH SET SCREWS FOR

SET SCREW ONLY

8 oz. (240 ml.) Oilers - 20284R

All types and sizes - 10310

LOWER CASTING FOR

2 oz. (60 ml.) Oilers - 20282R

Type “E” with ¼ NPT side hole only - 10304
Type “E” with ¼ BSPT side hole only - 14243

PIPE PLUG FOR

Type “EB” ¼ NPT - 10321

Type “EB” with ¼ NPT side and bottom holes - 10306
Type “EB” with ¼ BSPT side and bottom holes - 14241

Type “EB” ¼ BSPT - 14201

“E” & EB” OPTO-MATIC

REPLACEMENT PARTS LIST

LOWER CASTING FOR

Type “EH” with ¼ NPT side hole only - 20330R
Type “EH” with ¼ BSPT side hole only - 22544R
Type “EHB” with ¼ NPT side and bottom holes - 20331R

PIPE PLUG FOR

Type “EHB” ¼ NPT - 10321

2 oz. (60 ml.) Oilers - 20327R

RESERVOIR FOR

8 oz. (240 ml.) Oilers - 20329R

4 oz. (120 ml.) Oilers - 20328R

UPPER CASTING WITH SET SCREWS FOR

SET SCREW ONLY

All types and sizes - 10310

All types and sizes - 20315R

“EH” & EHB” OPTO-MATIC

REPLACEMENT PARTS LIST

3.  Loosen set screws on reservoir assembly. Remove 

reservoir assembly from lower casting.

4.  Be sure all connecting hardware is free from 

contaminants (burrs, chips, dirt, etc.) to prevent 
clogging or damage to the equipment to be lubricated.

5.  Connect lower casting to bearing chamber either 

through the side connection, Type E and EH oilers 
(Fig. 2) or the bottom connection, Type EB and 
EHB oilers (Fig. 3). Use thread compound on 
threaded areas.

6.  Verify the lower casting is level and parallel with 

desired oil level (Fig. 2 and 3). Make necessary 
adjustments if needed until lower casting is level.

2.  Determine proper oil level, which may be indicated 

on the equipment with an arrow. If that is not the case, 
engineering drawings or the equipment’s operator 
manual can provide the information. Indicate proper 
oil level on equipment using a marking device such 
as; a marker, scribe, paint, etc.

7.  From the oil level mark indicated on the equipment, 

use a level to put a mark on the outside of the Opto-
Matic lower casting to indicate where the oil level 
should be (Fig 4).

8.  Measure the distance between Opto-Matic Oiler 

casting edge and top edge of spout angle (Fig 5). 
Mark this distance above the original line made in 
step 7 on the outside of the Opto-Matic lower casting 
(Fig. 6). Now the bottom of the reservoir assembly 
can be used as an indicator of oil level. 

9.  Fill the equipment bearing chamber through the lower 

casting until the oil level reaches just below the mark 
made in step 7 on the lower casting. DO NOT fill at 
or above this mark as it will cause your equipment to 
have a high oil level.

10. Use a funnel to fill the reservoir assembly 2/3rds 

with the recommended oil. 

11. Place thumb over reservoir spout, invert, and insert 

on lower casting assembly at the point where the 
bottom edge of the reservoir assembly is at the level 
“X” mark from step 8. Quickly tighten set screws on 
the side of the reservoir assembly.

12. Start up equipment to verify proper oil level is 

being maintained.

1.  Prior to installing the Opto-Matic Oiler, shaft rotation 

direction must be determined, typically indicated by an 
arrow on the casting of the equipment. Install oiler on 
the side of the equipment facing the direction of shaft 
rotation to prevent misfeeding of the oiler (Fig 1).

Fig. 4

Level Line

Oil Level

Fig. 5

X

Fig. 6

Mark from
step 7

Mark Level “X”

TRICO CORPORATION

 1235 Hickory St., Pewaukee, WI 53072  Phone: (262) 691-9336

www.tricocorp.com

Fig. 1

Direction of shaft rotation