Steel Body, Automatic Wood Pellet Feed Hot Water Boiler Operation and Maintenance
Manual
Systems to be installed with Single Serpentine Hot Water Storage Tank:
In systems to be installed with a
single-serpentine boiler, the hot
water coming out of the tank should
be
connected to
the
upper
connection point of the boiler coil
and warm water which has returned
to the boiler should be connected to
the lower connection point. Pressure
reducer, safety valve and expansion
tank must be installed in the city water line entering the boiler.
Systems to be installed with Double Serpentine Hot Water Storage Tank:
In the systems to be installed with
double serpentine boiler, there are
two different serpentine groups in
the tank. The energy source
(usually solar energy, geothermal,
etc.) that will work continuously on
the lower serpentine can be
connected to the upper serpentine
and the boiler can be connected.
Pressure reducer, safety valve and
expansion tank must be installed in
the city water line entering the
boiler.