Steel Body, Automatic Wood Pellet Feed Hot Water Boiler Operation and Maintenance 
Manual 

BOILER SPECIFICATIONS 

 

 
 
 

 

 

 
 
 
 

 

 

Ecopel 24

Ecopel 36

Ecopel 48

Fuel Specifications
Maximum Power

kW

24

36

48

Minimum Power

kW

7,2

10,8

14,4

Efficiency at Max. Power

%

94,12

94,38

94,33

Hopper Volume

lt

Water Volume

lt

130

Boiler Weight

kg

450

Necessary

Pa

10

Draft

°C

132

Minimum Return Temperature

°C

Maximum Operating Pressure

bar

Test Pressure

bar

Temperature Control Range

°C

Maximum Operating Temperature

°C

Heating Line Flow/Return

inch

1 ¼"

Filling/Discharging Line

inch

Electricty 

V AC/Hz

Width (W)

mm

960

960

1020

Depth (D)

mm

700

700

700

Height (H)

mm

1115

1230

1415

Height of Flow Line (H

1

)

mm

960

1085

1270

Height of Return Line (H

2

)

mm

195

195

195

Height of Filling/Dischargin Line (H

3

)

mm

190

190

190

Distance between Flow/Return Line (W

1

)

mm

745

745

807

Height of Flue (H

4

)

mm

960

1020

1130

Width Including Cleaning Arm (W

2

)

mm

1015

1015

1080

Depth Including Flue (D

2

)

mm

755

755

755

Flue Diameter

mm

128

128

150

We reserve the right to make changes in dimensions.

D

im

en

si

o

n

s

TECHNICAL SPECIFICATIONS

ÜNMAK - ECOPEL

Wood Pellet

40

3

4.3

1"

40-80

80

½"

230/50

Summary of Contents for Ecopel

Page 1: ...el Compact Pellet Boiler Installation and User Manual NL SOY Yap Malzemeleri Sanayi ve Ticaret Ltd ti Pancar Organize Sanayi B lgesi 2 Etap No 2 Torbal ZM R Tel 444 35 32 Faks 0232 469 2412 www unmak...

Page 2: ...RANSPORTATION 5 INSTALLATION LOCATION SELECTION 6 SAFETY WARNINGS 8 ELECTRICAL INSTALLATION INSTRUCTIONS 10 INFORMATION ON COMBUSTION 11 BOILER SPECIFICATIONS 13 RULES FOR HEATING INSTALLATION 15 CONT...

Page 3: ...Operation and Maintenance Manual This booklet is covers below models ECOPEL 24 36 48 For Initial Start up Warranty Start up and Failure Notices please contact your local Authorized Service Centre or C...

Page 4: ...for burning wood pellets only 6 8 10 mm diameter wood pellets are suitable for burning These boilers are only used for heating the heating system they are not suitable for direct domestic water heatin...

Page 5: ...ATTENTION A hazardous situation may occur and failure to follow the precautions could result in minor personal injury or property damage WARNING Trapping of hands and feet should be avoided during tra...

Page 6: ...he product must be of sufficient capacity In order to prevent damage to boiler outer plates and boiler during transportation help from the transport equipment such as forklift or pallet truck The cent...

Page 7: ...hting is provided a system should be installed that does not dazzle but illuminates the apartment thoroughly The main switch and panels of the boiler room shall be placed around the entrance door and...

Page 8: ...unker and to work comfortably A At least 80 cm to allow convenient use of the boiler cleaning arm and service intervention B The burner assembly is at least 100 cm C At least 80 cm in order to make fl...

Page 9: ...ed from inside and outside and the cylindrical pipe is inserted into the rectangular chimney Fresh air must be provided to the area where the boiler is installed The dimensions specified in this manua...

Page 10: ...nd therefore permanent damage Water should not be drained in the installation unless it is for maintenance or risk of freezing The system design should ensure that the ratio between the installation w...

Page 11: ...rol cabinet must be connected to a wall panel with suitable grounding equipment All electrical connections must be made by authorized personnel in accordance with local regulations For each boiler roo...

Page 12: ...nnected to an independent chimney which can provide minimum desired minimum draft It should be measured in 20 Pa with a manometer The part of the waste gas line between the boiler and the chimney shou...

Page 13: ...bove the tiled roofs Chimney without chimney hood and chimney hood Incorrectly installed chimney and correctly installed chimney and chimney head DANGER Inadequate flue gas system can cause serious in...

Page 14: ...Maximum Operating Temperature C Heating Line Flow Return inch 1 Filling Discharging Line inch Electricty V AC Hz Width W mm 960 960 1020 Depth D mm 700 700 700 Height H mm 1115 1230 1415 Height of Flo...

Page 15: ...allowed to reach this group Manometer can be seen when the left front door of the boiler is opened Water pressure can be observed from the manometer while adding water When the left front door of the...

Page 16: ...culation pump expansion tank safety valve is included with the boiler and you do not need to add to the installation separately The wiring diagram can be simply installed as shown For installations wi...

Page 17: ...lower connection point Pressure reducer safety valve and expansion tank must be installed in the city water line entering the boiler Systems to be installed with Double Serpentine Hot Water Storage T...

Page 18: ...e heating installation including installation pipes and radiators must be protected against corrosion Oxygen in the installation water causes rust and consequently material loss as a result of oxidati...

Page 19: ...tion only when the installation is cold Considerations for central heating connected to old installations In a heating system that is used for a long time a protective layer black magnetite is formed...

Page 20: ...hen the enter button is pressed in the menu it accepts the value written on the screen or enters into the menu displayed on the screen Escape Button Escape button is used to cancel without saving the...

Page 21: ...rbox standby time 0 0 2000 sec P1 3 Fan speed 600 3000 rpm P1 4 Transition time 0 600 sec Power 2 P2 1 Gearbox feeding time 1 0 40 0 sec P2 2 Gearbox standby time 0 0 2000 sec P2 3 Fan speed 600 3000...

Page 22: ...wn temperature 0 100 C V4 3 Pump run time at temperature rise 0 255 sec V4 4 Pump standby time at temperature rise 0 255 sec V4 7 Shut down time at power 0 sleep mode 0 20 min 0 cancel Various Setting...

Page 23: ...empty there may not be an ignition at first After the error message appears on the screen reset it by pressing the ESC button for 5 seconds After the firing phases have passed the boiler goes to power...

Page 24: ...it must be repaired and sealed Check the fan for proper operation An improperly balanced balanced fan makes periodic noises If there is fuel dust or ashes collected between the vanes of the fan it is...

Page 25: ...he A1 bolts and remove the fan Then taking the A2 bolts gently remove the fan throat so that it does not hit the igniter You can remove the igniter by loosening the small setscrew bolt in the round ig...

Page 26: ...r covers Cover wicks may be worn Covers may be deformed Replace the wicks Make sure that the combustion does not stand on the covers For deformed covers seek assistance from a specialist garage Failur...

Reviews: