background image

INSTALLATION & OPERATION MANUAL FOR 

Charbroilers 

 

 

 

 

 

 

MODELS 

MLS 

VCCB25 

ML-114540

 

VCCB30 

ML-114541

 

VCCB36 

ML-114542

 

VCCB47 

ML-114543

 

VCCB60 

ML-114544

 

VCCB72 

ML-114545

 

www.vulcanhart.com 

 

 
 

 

 

 

MODELS 

MLS 

SCB25 

ML-767100

 

SCB30 

ML-767101

 

SCB36 

ML-767102

 

SCB47 

ML-767103

 

SCB60 

ML-767104

 

SCB72 

ML-767105

 

www.wolfrange.com 

 

 

 

 

 
 
 
 
 
 

 

ITW Food Equipment Group, LLC 
An Illinois Tool Works Company 
701 South Ridge Avenue, Troy, OH 45374 

FORM F-36952 (06-06)

 

Summary of Contents for ML-114540

Page 1: ...VCCB47 ML 114543 VCCB60 ML 114544 VCCB72 ML 114545 www vulcanhart com MODELS MLS SCB25 ML 767100 SCB30 ML 767101 SCB36 ML 767102 SCB47 ML 767103 SCB60 ML 767104 SCB72 ML 767105 www wolfrange com ITW Food Equipment Group LLC An Illinois Tool Works Company 701 South Ridge Avenue Troy OH 45374 FORM F 36952 06 06 ...

Page 2: ...RTANT IN THE EVENT A GAS ODOR IS DETECTED SHUT DOWN UNITS AT MAIN SHUTOFF VALVE AND CONTACT THE LOCAL GAS COMPANY OR GAS SUPPLIER FOR SERVICE FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE INJURY OR DEATH READ THE INS...

Page 3: ...f and reduce flaring when tilted towards the front A grease drawer is provided to collect fat run off it opens to the front for inspection or drain off Model Number of Burners BTU hr Input Rating VCCB25 SCB25 4 58 000 VCCB30 SCB30 5 72 500 VCCB36 SCB36 6 87 000 VCCB47 SCB47 8 116 000 VCCB60 SCB60 11 159 500 VCCB72 SCB72 13 188 500 INSTALLATION UNPACKING Immediately after unpacking check for possib...

Page 4: ... the United States of America 1 State and local codes 2 National Fuel Gas Code ANSI Z223 1 NFPA 54 latest edition This shall include but not be limited to NFPA 54 Section 10 3 5 2 for Venting Copies may be obtained from The American Gas Association Accredited Standards Committee Z223 400 N Capital St NW Washington DC 20001 or the Secretary Standards Council NFPA 1 Batterymarch Park Quincy MA 02169...

Page 5: ...o the gas supply on both the left and right sides to provide adequate gas flow A pressure regulator is supplied and must be installed outside of the broiler when making the gas supply connection Standard orifices are set for 5 WC Water Column for Natural Gas 10 WC Water Column for Propane Use the 1 8 pipe tap on the burner manifold for checking pressure Make sure the gas piping is clean and free o...

Page 6: ...RS Charbroilers mounted on stands with casters must use a flexible connector not supplied that complies with the Standard for Connectors for Movable Gas Appliances ANSI Z21 69 CSA 6 16 and a quick disconnect device that complies with the Standard for Quick Disconnect Devices for use With Gas Fuel ANSI Z21 41 CSA 6 9 In addition adequate means must be provided to limit movement of the broiler witho...

Page 7: ...ve energy The charbroiler is a free vented appliance All products of combustion and the heat generated by the burners pass through the grates When meat is placed on the grates this blocks the venting and causes a temperature build up The charbroiler operates most efficiently with valves turned down to 1 3 or LIGHTING THE GAS PILOT Fig 3 Pilot 1 Turn the individual burner gas valves off and wait 5 ...

Page 8: ...ler can be removed for cleaning use wire brush Stainless steel surfaces may be cleaned using damp cloth with mild detergent and water solution Places where fat grease or food can accumulate must be cleaned regularly MAINTENANCE WARNING THE CHARBROILER AND ITS PARTS ARE HOT USE CARE WHEN OPERATING CLEANING OR SERVICING THE CHARBROILER VENT SYSTEM At least twice a year the exhaust hood venting syste...

Reviews: