LEVELING 

If the charbroiler is equipped with legs or is mounted on the optional stand equipped with 
legs, turn the feet at the bottom of the legs in or out to level the broiler in the final 
installed location.  If the broiler is mounted on the optional stand equipped with casters, 
position the charbroiler on a level floor. 

VENTILATION HOOD 

The broiler should be installed under a suitable ventilation hood. For safe operation and 
proper ventilation, keep the space between the charbroiler and vent hood free from any 
obstructions. 

GAS CONNECTION 

The data plate on the lower right side of the charbroiler indicates the type of gas your unit 
is equipped to burn.  DO NOT connect to any other gas type. 

CAUTION:  All gas supply connections and any pipe joint compound must be 
resistant to the action of propane. 

Purge the supply line to clean out any dust, dirt, or any foreign matter before connecting 
the line to the unit. 

Codes require that a gas shut-off valve be installed in the gas line ahead of the 
charbroiler.  The gas supply line must be at least the equivalent of ¾” iron pipe.  72-inch 
units should be connected to the gas supply on both the left and right sides to provide 
adequate gas flow.   

A pressure regulator is supplied and must be installed outside of the broiler when making 
the gas supply connection.  Standard orifices are set for 5"WC (Water Column) for 
Natural Gas — 10"WC (Water Column) for Propane.  Use the 

1

/

8

” pipe tap on the burner 

manifold for checking pressure.  Make sure the gas piping is clean and free of 
obstructions, dirt, and piping compound. 

An adequate gas supply is necessary.  Undersized or low pressure lines will restrict the 
volume of gas required for satisfactory performance.  A maximum supply pressure of 7" 
W.C. for natural gas and 11" W.C. for propane gas is recommended.  With all units 
operating simultaneously, the manifold pressure on all units should not show any 
appreciable drop.   

When testing the gas supply piping system, if test pressures exceed ½ psig (3.45 kPa), 
the charbroiler and its individual shutoff valve must be disconnected from the gas supply 
piping system.  When test pressures are ½ psig (3.45 kPa) or less, the charbroiler must 
be isolated from the gas supply piping system by closing its individual manual shut-off 
valve during any pressure testing of the system. 

WARNING

:  PRIOR TO LIGHTING, CHECK ALL JOINTS IN THE GAS SUPPLY LINE FOR 

LEAKS.  USE SOAP AND WATER SOLUTION.  DO NOT USE AN OPEN FLAME. 

 

- 5 - 

Summary of Contents for ML-114540

Page 1: ...VCCB47 ML 114543 VCCB60 ML 114544 VCCB72 ML 114545 www vulcanhart com MODELS MLS SCB25 ML 767100 SCB30 ML 767101 SCB36 ML 767102 SCB47 ML 767103 SCB60 ML 767104 SCB72 ML 767105 www wolfrange com ITW Food Equipment Group LLC An Illinois Tool Works Company 701 South Ridge Avenue Troy OH 45374 FORM F 36952 06 06 ...

Page 2: ...RTANT IN THE EVENT A GAS ODOR IS DETECTED SHUT DOWN UNITS AT MAIN SHUTOFF VALVE AND CONTACT THE LOCAL GAS COMPANY OR GAS SUPPLIER FOR SERVICE FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE INJURY OR DEATH READ THE INS...

Page 3: ...f and reduce flaring when tilted towards the front A grease drawer is provided to collect fat run off it opens to the front for inspection or drain off Model Number of Burners BTU hr Input Rating VCCB25 SCB25 4 58 000 VCCB30 SCB30 5 72 500 VCCB36 SCB36 6 87 000 VCCB47 SCB47 8 116 000 VCCB60 SCB60 11 159 500 VCCB72 SCB72 13 188 500 INSTALLATION UNPACKING Immediately after unpacking check for possib...

Page 4: ... the United States of America 1 State and local codes 2 National Fuel Gas Code ANSI Z223 1 NFPA 54 latest edition This shall include but not be limited to NFPA 54 Section 10 3 5 2 for Venting Copies may be obtained from The American Gas Association Accredited Standards Committee Z223 400 N Capital St NW Washington DC 20001 or the Secretary Standards Council NFPA 1 Batterymarch Park Quincy MA 02169...

Page 5: ...o the gas supply on both the left and right sides to provide adequate gas flow A pressure regulator is supplied and must be installed outside of the broiler when making the gas supply connection Standard orifices are set for 5 WC Water Column for Natural Gas 10 WC Water Column for Propane Use the 1 8 pipe tap on the burner manifold for checking pressure Make sure the gas piping is clean and free o...

Page 6: ...RS Charbroilers mounted on stands with casters must use a flexible connector not supplied that complies with the Standard for Connectors for Movable Gas Appliances ANSI Z21 69 CSA 6 16 and a quick disconnect device that complies with the Standard for Quick Disconnect Devices for use With Gas Fuel ANSI Z21 41 CSA 6 9 In addition adequate means must be provided to limit movement of the broiler witho...

Page 7: ...ve energy The charbroiler is a free vented appliance All products of combustion and the heat generated by the burners pass through the grates When meat is placed on the grates this blocks the venting and causes a temperature build up The charbroiler operates most efficiently with valves turned down to 1 3 or LIGHTING THE GAS PILOT Fig 3 Pilot 1 Turn the individual burner gas valves off and wait 5 ...

Page 8: ...ler can be removed for cleaning use wire brush Stainless steel surfaces may be cleaned using damp cloth with mild detergent and water solution Places where fat grease or food can accumulate must be cleaned regularly MAINTENANCE WARNING THE CHARBROILER AND ITS PARTS ARE HOT USE CARE WHEN OPERATING CLEANING OR SERVICING THE CHARBROILER VENT SYSTEM At least twice a year the exhaust hood venting syste...

Reviews: