207
Drink Dispenser E-Protocol will be supported.
System Configuration
Communication settings
E-Protocol
Baud Rate
2400bps
Data Bits
8
Parity
None
Stop Bits
1
Handshaking
None
Cable pin layout
POS
Dispenser
3
TXD
2
RXD
2
RXD
3
TXD
5
GND
5
GND
Additional Programs
Configure > External Device > Drink Dispenser > Model: = E-Protocol
NEW!
Program > PLU > Type > Dispense item
NEW!
Only PLUs with this setting will be sent to the dispenser.
Protocol data
[Operation at the POS]
1.
Clerk 1 sign on.
2.
Enter PLU 1 (Qty 2).
3.
Enter PLU 2 (Qty 3).
4.
Enter VOID PLU 1 (Qty 1).
5.
Store or Media close.
POS
Dispenser
Q00020010001 (*1)
--->
(Time out 3 sec)
<---
R = success or "F" = fail
Q00030010002 (*1)
--->
(Time out 3 sec)
<---
R = success or "F" = fail
q00010010001 (*1)
--->
<---
R = success or "F" = fail
(*1) "0001" and "0002" are PLU numbers.
The value is fixed to 4 Bytes, and it is PLU number minus 1 (Max. 9999).
ex. PLU code 000000000000000001 = "0","0","0","1" (30h, 30h, 30h, 31h)
ex. PLU code 000000000000000123 = "0","1","2","3" (30h, 31h, 32h, 33h)
Drink dispenser
HX-series
Serial (RS-232C)